6500 Protek, 6500 Datasheet

Digital Multimeters 50K COUNT HAND HELD WITH RS232 INTERFACE

6500

Manufacturer Part Number
6500
Description
Digital Multimeters 50K COUNT HAND HELD WITH RS232 INTERFACE
Manufacturer
Protek
Datasheet

Specifications of 6500

Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
6500-100PH8
Manufacturer:
HIFN
Quantity:
910
Part Number:
6500-100PH8
Manufacturer:
HIFN
Quantity:
20 000
Company:
Part Number:
6500-100PH8
Quantity:
9 969
Part Number:
65000-018
Manufacturer:
Amphenol FCI
Quantity:
311
Part Number:
65000-019
Manufacturer:
Amphenol FCI
Quantity:
543
Part Number:
65001-006
Manufacturer:
Amphenol FCI
Quantity:
470
Part Number:
65001-016
Manufacturer:
Amphenol FCI
Quantity:
470
DC mV
Ranges:
Accuracy:
DC Volts
Ranges:
Accuracy:
Input Impedance:
AC mV
Ranges:
AC mV Accuracy:
40Hz to 1Khz: ±(0.5% + 40d), 1KHz to 10KHz: ±(1.0% + 40d),
10KHz to 20KHz: ±(2.5% + 40d)
Input Impedance:
AC Volts
Ranges:
AC Volts Accuracy (5V to 500V ranges):
40Hz to 1KHz: ±(0.5% +40d), 1KHz to 10KHz: ±(1.0% + 40d),
10KHz to 20KHz: ±(2.5% + 40d)
Max. Input Voltage:
Input Impedance:
DC µA:
Ranges:
Accuracy:
Overload Protection:
DC mA
Ranges:
Accuracy:
Overload Protection:
50mV, 500mV;
5V, 50V, 500V, 1000V;
50mV, 500mV;
5V, 50V, 500V, 1000V;
500µA, 5000µA;
50mA, 500mA;
±(0.03% + 6d);
±(0.03% + 6d);
±(0.15% + 1d)
±(0.15% + 10d)
10MΩ
1GΩ
10MΩ
1000V DC or AC peak
0.5A/250V fuse
0.5A/250V fuse
Best Resolution:
Best Resolution:
Best Resolution:
Best Resolution:
Input Impedance:
Max. Input Voltage:
Best Resolution:
Best Resolution:
1µV
1µV
1.0µA
10.0nA
1GΩ
1000V DC
100µV
100µV
DC A
Ranges:
Accuracy:
Overload Protection:
AC µA
Ranges:
Accuracy:
Overload Protection:
AC mA
Ranges:
Accuracy:
Overload Protection:
AC A
Ranges:
Accuracy:
40Hz to 1KHz 5A: ±(0.75% + 20d)
40Hz to 1KHz 10A: ±(0.75% + 20d)
Overload Protection:
Resistance
Ranges:
Best Resolution:
Max. Input Voltage:
Continuity Buzzer
Buzzer Will Sound:
Capacitance
Ranges:
Best Resolution:
Maximum Input Volts:
6500
5A, 10A;
500µA, 5000µA;
50mA, 500mA;
5A, 10A;
500Ω, 5KΩ, 50KΩ, 500KΩ, 5MΩ, 50MΩ
50nF, 500nF, 5µF, 50µF, 500µF, 5000µF
50,000 count and 50 segment bar graph backlit display
Basic DC accuracy is ±0.03%
RS232 interface with software and cable
dBm measurement with 4Ω to 1200Ω reference resistances
AC and (AC+DC) TRUE RMS measurement
Measures frequency, Duty cycle and Capacitance
Cat III 1000V
Max/Min and Relative measurements
Auto power off and backlit display
±(0.5% + 10d)
±(0.75% + 10d) 40Hz to 1KHz
±(0.75% + 20d) 40Hz to 1KHz
10.0mΩ;
10pF;
Best Resolution:
Best Resolution:
< 60Ω resistance
250V
10A/250V fuse
0.5A/250V fuse
0.5A/250V fuse
10A/250V fuse
250V
Best Resolution:
Accuracy:
Best Resolution:
Accuracy:
50,000 Count Multimeter
±(1.0% + 5d)
100µA
100µA
±(0.1% + 5d)
1.0µA
10.0nA
45 Smith Street, Englewood, NJ 07631 Tel: 201-818-7711 Fax: 201-760-9888
Diode Test
Range:
Accuracy:
Logic Frequency
Sensitivity:
Accuracy:
Frequency Range:
Frequency
Ranges:
Accuracy:
Input Sensitivities (Range/Sensitivity):
(500mV / 0.1V), (5V / 0.5V), (50V / 4V), (500V / 40V),
(1000V / 400V), (5000µA / 1000µA), (500mA / 100mA)
Duty Cycle
Range:
Accuracy:
General Specifications
Operating Temperature:
0 to 30ºC (32 to 86ºF) @ 80% Relative Humidity
31 to 51ºC (87 to 124ºF) @ 50% Relative Humidity
Power:
Size:
Weight:
Accessories:
software CD
Website: www.protektest.com Email: sales@protektest.com
7.9" (H) x 3.94" (W) x 1.57" (D)
(6) AAA Batteries
2.5V;
0 to 90%;
1.23 lbs
5Hz to 200KHz;
±(1.0% + 5d);
±(0.006% + 4d)
±(0.006% + 4d)
±10%
+2V to +5V Square wave
Resolution:
Manual, test leads, RS232 cable and
Resolution:
5Hz to 2MHz
S P E C I F I C A T I O N S
Test Current:
Best Resolution:
0.1mV
0.01%
Protek Test & Measurement
Approx. 0.7mA
0.001Hz
6500
23