MSO3054 Tektronix, MSO3054 Datasheet
MSO3054
Specifications of MSO3054
MSO3054 Summary of contents
Page 1
... With Digital Phosphor technology for fast visualization of signal anomalies, Wave Inspector controls for rapid waveform navigation, and automated ® serial bus and power analysis, the MSO/DPO3000 Oscilloscope Series from Tektronix provides the feature-rich tools you need to simplify and speed debug of your complex design. C, SPI, 2 ...
Page 2
... Capture – Triggering on a specific transmit data packet going across an RS-232 bus. A complete set of triggers, including triggers for specific serial packet content, ensures you quickly capture your event of interest ...
Page 3
... For extended analysis, National Instrument’s LabVIEW SignalExpress™ Tektronix Edition provides over 200 built-in functions including time and frequency domain analysis, limit testing, data logging, and customizable reports. ...
Page 4
... Once again, turning the control further makes the waveform scroll faster and changing direction is as simple as turning the control the other way. 4 www.tektronix.com Search step 1: You define what you would like to find. Search step 2: Wave Inspector automatically searches through the record and marks each event with a hollow white triangle ...
Page 5
... One common problem shared by both logic analyzers and mixed-signal oscilloscopes is determining if data is a one or a zero when zoomed in far enough that the digital trace stays flat all the way across the display. The MSO3000 Series has color-coded digital traces, displaying ones in green and zeros in blue. www.tektronix.com 5 ...
Page 6
... USB keyboard. By simply placing digital waveforms next to each other, they form a group. 6 www.tektronix.com The P6316 MSO probe offers two eight-channel pods to simplify connecting to your device. Once a group is formed, you can position all the channels contained in that group collectively ...
Page 7
... MSO/DPO3000 Series, you can have the oscilloscope automatically search through the acquired data for user-defined criteria including serial packet content. Each occurrence is highlighted by a search mark. Rapid navigation between marks is as simple as pressing the Previous (←) and Next (→) buttons on the front panel. S/LJ/RJ/TDM 2 www.tektronix.com 7 ...
Page 8
... PC or complex software setup is required. 8 www.tektronix.com Viewing an NTSC video signal. Notice the intensity-graded view provided by the DPO’s ability to represent time, amplitude, and distribution of amplitude over time. Video Design and Development ...
Page 9
... The TekVPI interface enables direct attachment of current probes without requiring a separate power supply. TekVPI probes can be controlled remotely through USB, GPIB, or Ethernet, enabling more versatile solutions in ATE environments. www.tektronix.com 9 ...
Page 10
... Data Sheet NI LabVIEW SignalExpress™ Tektronix Edition is a fully interactive measurement acquisition and analysis software developed jointly with National Instruments and optimized for the MSO/DPO Series. Extended Analysis Acquiring data and measurements from the MSO/DPO3000 Series is as simple as connecting a USB cable from the oscilloscope to your PC. Key software applications - NI LabVIEW SignalExpress™ ...
Page 11
... Maximum Record Length (Main, all channels) Maximum Sample Rate (MagniVu, all channels) Maximum Record Length (MagniVu, all channels) Minimum Detectable Pulse Width Channel-to-Channel Skew MSO3032 MSO3034 MSO3054 DPO3032 DPO3034 DPO3054 2 4 300 MHz 300 MHz 500 MHz 1.17 ns 1.17 ns 700 ps 20 MHz, 150 MHz ...
Page 12
... Mb/s (by LIN definition, 20 kb/s). Parallel (available Trigger on a parallel bus data value. Parallel bus can be from bits in size. Binary and Hex radices are supported. on MSO models only) 12 www.tektronix.com Trigger Sensitivity Characteristic Description Internal DC Coupled 0.5 div from MHz, increasing to 1 div at ...
Page 13
... Digital Phosphor Oscilloscopes — MSO3000 Series, DPO3000 Series Waveform Math Characteristic Arithmetic Math Functions FFT Advanced Math Software Product NI LabVIEW SignalExpress™ Tektronix Edition OpenChoice ® Desktop , I , True RMS Crest Factor IVI Driver eScope Description Add, subtract, multiply, and divide waveforms. ...
Page 14
... Power Consumption 120 W maximum Optional TekVPI ® Output Voltage External Power Output Current Supply* Power Consumption Required when total oscilloscope probe power usage exceeds www.tektronix.com Physical Characteristics Dimensions Height Width Depth Weight Net Shipping Rackmount Configuration Cooling Clearance Environmental Characteristic Temperature ...
Page 15
... MSO3034 300 MHz, 2.5 GS/s, 5M record length, 4+16 channel mixed-signal oscilloscope MSO3054 500 MHz, 2.5 GS/s, 5M record length, 4+16 channel mixed-signal oscilloscope All Models Include: One P6139A 500 MHz, 10x Passive Probe per Analog Channel, Front Cover (200-5052-xx), User Manual, Documentation CD (063-4104-xx), OpenChoice Desktop Software, NI LabVIEW SignalExpress™ ...
Page 16
... Required when total oscilloscope probe power usage exceeds 20 W. Power cord not included. 5 Warranty Three-year warranty covering all parts and labor, excluding probes. Product(s) are manufactured in ISO registered facilities. Product(s) complies with IEEE Standard 488.1-1987, RS-232-C, and with Tektronix Standard Codes and Formats. ...
Page 17
... Digital Phosphor Oscilloscopes — MSO3000 Series, DPO3000 Series www.tektronix.com 17 ...
Page 18
... Please visit www.tektronix.com Copyright © Tektronix, Inc. All rights reserved. Tektronix products are covered by U.S. and foreign patents, issued and pending. Information in this publication supersedes that in all previously published material. ...