TDS3GV Tektronix, TDS3GV Datasheet

Benchtop Oscilloscopes GPIB VGA RS-232

TDS3GV

Manufacturer Part Number
TDS3GV
Description
Benchtop Oscilloscopes GPIB VGA RS-232
Manufacturer
Tektronix
Datasheet

Specifications of TDS3GV

Equipment Type
Accessory - GPIB, VGA, RS-232 Interface Module for TDS3000C Series
Module Type
Communication
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
Digital phosphor oscilloscopes
Digital Phosphor Oscilloscopes
The TDS3000B Series of Digital Phosphor Oscilloscopes
Provides Unmatched Performance and Portability
at an Affordable Price
The TDS3000B packs the power of a
DPO, digital real-time (DRT) sampling
technology, WaveAlert waveform anomaly
detection, OpenChoice documentation
and analysis solutions and five application-
specific modules into a lightweight,
battery-capable design.
A DPO Provides a Greater Level
of Insight into Complex Signals
The TDS3000B Series DPO delivers
3,600 wfms/s continuous waveform
capture rate to capture glitches and
infrequent events three times faster than
comparable oscilloscopes. Some oscillo-
scope vendors claim high waveform
capture rates for short bursts of time,
but only DPOs can deliver these fast
waveform capture rates on a continuous
basis – saving minutes, hours or even
days by quickly revealing the nature of
TDS3012B • TDS3014B • TDS3024B • TDS3032B • TDS3034B • TDS3044B • TDS3052B • TDS3054B • TDS3064B
faults so advanced triggers can be
applied to isolate them.
In addition, the TDS3000B DPO’s
real-time intensity grading highlights the
details about the “history” of a signal’s
activity, making it easier to understand
the characteristics of the waveforms
you’ve captured.
The TDS3000B DPO provides unmatched
insight into complex signal behavior,
such as metastable events.
100 to 600 MHz Bandwidths
5 GS/s Maximum Real-time
Sample Rate, with Sin(x)/x
Interpolation
3,600 wfms/s Continuous
Waveform Capture Rate
2 or 4 Channels
Full VGA Color LCD
25 Automatic Measurements
FFT Standard
Multi-language User Interface
QuickMenu Graphical User
Interface for Easy Operation
WaveAlert
Anomaly Detection
OpenChoice
Simplify Instrument Control,
Documentation and Analysis
– e*Scope
– Built-in Ethernet Port
– GPIB, RS232, VGA
– TDSPCS1 OpenChoice
– WaveStar
– Integration with Third-party
Application Modules for
Specialized Analysis
– Advanced Analysis Module
– Limit Testing Module
– Telecommunications Mask
– Extended Video Module
– 601 Serial Digital Video Module
Optional Internal Battery
Operation up to 3 Hours
Plug-in Printer for Portable
Documentation of Results
TekProbe
Active, Differential and Current
Probes for Automatic Scaling
and Units
Digital Design, Debug and Test
Video Installation and Service
Power Supply Design
Education and Training
Telecommunications Mask Testing
Manufacturing Test
Features & Benefits
Applications
Remote Control
Software
Software
Testing Module
®
Interface Supports
Automatic Waveform
®
®
Web-based
Solutions
Software

TDS3GV Summary of contents

Page 1

... Digital Phosphor Oscilloscopes TDS3012B • TDS3014B • TDS3024B • TDS3032B • TDS3034B • TDS3044B • TDS3052B • TDS3054B • TDS3064B The TDS3000B Series of Digital Phosphor Oscilloscopes Provides Unmatched Performance and Portability at an Affordable Price The TDS3000B packs the power of a DPO, digital real-time (DRT) sampling ...

Page 2

... The result – a complete view of your signal to speed debug and characterization. Digital Phosphor Oscilloscopes • www.tektronix.com/tds3000b 2 An increase in performance from 500 to 600 MHz bandwidth offers a 20% improvement in rise-time measurement accuracy, as illustrated with these measurements rising edge ...

Page 3

... TDS3000B oscilloscope from anywhere, using the Internet and your PC. With the optional TDS3GV Communication Module, floppy disk, TDSPCS1 OpenChoice Software and integration with third-party software, the TDS3000B Series provides you with multiple choices to easily capture, transfer, document and analyze your measurement results ...

Page 4

... Input Impedance Selections Time Base Range 10 s/div 10 s/div Time Base Accuracy Display Monitor (VGA) 4 Digital Phosphor Oscilloscopes • www.tektronix.com/tds3000b TDS3024B TDS3032B TDS3034B 200 MHz 300 MHz 300 MHz 2.5 GS/s 2.5 GS/s 2.5 GS points on all models 9 Bits on all models all models ± ...

Page 5

... STATE: Any logic state. Triggerable on rising or falling edge of a clock. Logic triggers can be used on combinations of 2 inputs (not 4). Digital Phosphor Oscilloscopes • www.tektronix.com/tds3000b Digital Phosphor Oscilloscopes Trace and identify ITU-R BT.601 video signals with the TDS3SDI 601 Serial Digital Video Module. Pulse – ...

Page 6

... TDSPCS1 OpenChoice PC Communication Software – A collection of programs that enable fast and easy transfer communication between MS Windows PCs and Tektronix oscilloscopes. Available in single-license packages and included in TDS3GV communication module. Minimum system require- ments: MS Windows 98 SE, XP Professional, ME, or 2000. MS Office 2000 or XP (for TDS toolbars ...

Page 7

... Requires TCPA300 probe amplifier. *4 Requires TCPA400 probe amplifier. Digital Phosphor Oscilloscopes • www.tektronix.com/tds3000b Digital Phosphor Oscilloscopes Tektronix probes are expressly designed for your oscilloscope, with identical quality standards and built-in compatibility for optimum performance. Language Options (includes front panel overlay) Opt. L0 – English. ...

Page 8

... U.S. and foreign patents, issued and pending. Information in this publi- cation supersedes that in all previously published material. Specification and price change privileges reserved. TEKTRONIX and TEK are registered trademarks of Tektronix, Inc. All other trade names referenced are the service marks, trademarks or registered trademarks of their respective companies. 08/05 ...