06715 Simpson, 06715 Datasheet - Page 57

Analog Panel Meters SHUNT 200 AMP 50 MV

06715

Manufacturer Part Number
06715
Description
Analog Panel Meters SHUNT 200 AMP 50 MV
Manufacturer
Simpson
Type
Current Shuntsr
Datasheets

Specifications of 06715

Equipment Type
Portable Shunt
Range
0 - 200
Accuracy
±1%
Current, Rating
200 A
Dimensions
6.00 in. L x 1.25 in. W x 1.60 in. D
Includes
5 ft. Leads
Resistance
0.065 Ohms
Screw Size
10-32
Voltage, Output
50 mV
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• Wide Variety of Control, Alarm, and Limit
• Calibration Not Affected by Steel Panel
• Rugged Metal Case for Rigorous Environments
• Commercially-Sealed, Moisture and Dust
Dimensions
Use
Mounting
Proof
4 - 1/2”-Model 3344AIXA & 3324AIXA
1
=
Panel Meter Cut-out Dimensions
Specifications
Accuracy:
Movement:
Suspension:
Tracking:
Repeatability:
Shielding:
Response Time:
Overload (1 sec.):
Overload (Continuous):
Dial:
Case:
Voltage Drop:
Pointer:
Scale Length:
Net Weight:
Control Point(s)
Adjustments:
Switching:
Differential:
Auto/Manual Reset:
Contacts/Output Relay:
Frequency Response:
Power:
Operating Temperature:
Circuit-to-Ground
Voltage:
NOTE:
3 - 1/2”-Model 3343AIXA & 3323AIXA
AC: ±3% of full scale; DC: ±2% F.S.
Annular, self-shielding
Pivot and jewel
±3%
Within 0.5% F.S.
Calibration is unaffected by magnetic panel mounting
1.5 seconds maximum above 10mA
AC: 7 amps; DC: 10 times F.S.
AC: 7 amps, DC: 1.5 times F.S.
Sharp clear scale. Each dial arc is calibrated to
track the specific type of movement used.
Sealed metal, plastic window
50mV
Black, knife-edge
4.05" (103.0mm)
17oz (0.48kg)
Single, high limit, 0-100% of arc; double, low limit 0-
95% of arc; high limit 5-100% of arc Adjustable to
within 4° of each other
Within 1% of indication
“On,” “Off” difference is within 0.5% of F.S.
Latching function can be enabled independently
for each relay by removing jumpers on terminal
block
DPDT relay contacts for each control point; Each
set of contacts rated at 5 amps, 120/240 VAC resistive.
50-1000Hz
108-132 VAC, 50-400Hz
+41°F to 122°F (5°C to +50°C)
250V rms maximum
DC meters meet ANSI specification C-39.1