37021 Simpson, 37021 Datasheet - Page 19

no-image

37021

Manufacturer Part Number
37021
Description
Analog Panel Meters AC XFMR 150/5 Amps
Manufacturer
Simpson
Type
Inductiver
Datasheets

Specifications of 37021

Dimensions
89.66 mm L x 96.01 mm H
Number Of Outputs
1
Power Rating
5 VA
Primary Voltage Rating
150 V
Termination Style
Screw Terminals
Accuracy
± 1 %
Current, Ratio
150:5
Diameter, Inside
3.78 in.
Diameter, Outside
3.53 in.
Frequency Response
50 to 400 Hz
Function
Current
Height
4.22 in.
Length
3.53 in.
Material, Stud
Brass
Primary Type
Current
Range, Measurement
150 A
Technology
Inductive
Thickness
2.15 in.
Transformer Type
Current
Width
0.071 in.
Input Current
150A
Turns Ratio
150
Frequency Range
50Hz To 400Hz
Transformer Mounting
Panel
Secondary Current Nom
5A
Mounting Type
Foot Mounted
Winding Configuration
150
Rohs Compliant
No
Current Ratio
150
Leaded Process Compatible
No
Output Current
5A
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
To monitor AC current

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
37021
Manufacturer:
ST
0
Part Number:
37021N
Manufacturer:
ST
Quantity:
5 510
Part Number:
37021N
Manufacturer:
FAR
Quantity:
5 510
• Four model types designed to fit a wide
• One meter to measure all your values
• Easy installation - software detection/
• Wide backlit LCD display for easy viewing
• Easy to use - four keys select all parameters
• Use for single or three-phase applications
range of applications
correction of wiring errors
INPUT
System
Voltages
Current
Measurement range
Operating Frequency
Harmonics
Input Loading
Overload
Auxiliary Supply
General Display
ENVIRONMENTAL
Temperature
Humidity
Programming
CT Primary
VT Primary
Pulse Outputs
Function
Pulse Length
Isolation
Scaling
ACCURACY
Current
5% to 120%FS
Voltage LN
20% to 120%FS
Voltage LL
20% to 120%FS
Watts
5% to 120%FS
VA
5% to 120%FS
var
5 % to 120%FS
PF
Frequency
Neutral Current
5% to 120%FS
Wh Register
VAh Register
Varh Register
Note:
MECHANICAL
Bezel
Depth
Panel Cutout
Weight
Height
Specifications
Measurement range
Voltage
Current
Voltage
Current
Standard
Optional
Output No. 1
Output No. 2
3-phase, 3 or 4 wire unbalanced load
120/208, 120/240, 277/480, 63/110
0.5% to 120%
5 amp from external CTs Fully Isolated
0.5% to 120%
45 to 65 Hz
Up to the 20th harmonic
Less than 0.1VA per phase
Less than 0.1VA per phase
x2 for 2 seconds max.
x40 for 1 second max.
115V±15% 45-65Hz
230V±15% 45-65Hz
Custom backlit supertwist LCD 3 lines of .47”
(12mm) digits plus .15” (3.8mm) legends
14°F to 149°F (-10°C to 65°C) operating
<75% RH non-condensing
5amp to 6500 amp
60v to 50,000v
2
Wh (G200, G300 & G400 only)
Total varh (G300 & G400 only)
100ms
2500V (50 Output No. 1 to Output No. 2)
Settable 1, 10 or 100 pulse output rate
All accuracies specified are ±1 digit
*Rdg = Reading
2.77” x 3.79” (w/ .28” lip)
2.83”
3.62” x 3.62”
14 oz.
3.79”
Per Phase
±0.2%FS
±1% Rdg*
±0.2%FS
±1% Rdg*
±0.3%FS
±1% Rdg*
±0.4%FS
±1% Rdg*
±0.6%FS
±1.5% Rdg*
±0.8%FS
±2% Rdg*
±0.2°
N/A
N/A
N/A
N/A
N/A
3 Phase
N/A
N/A
N/A
±0.6%FS
±1% Rdg*
±1%FS
±1.5% Rdg*
±1.5% FS
±2% Rdg
±0.2°FS
±0.05 Hz
±0.6% FS
±2% Rdg
Class 1
EN 61036
Class 2
Class 2
IEC 1268
more >>
15