H335-1-35-0-0-0 Simpson, H335-1-35-0-0-0 Datasheet

no-image

H335-1-35-0-0-0

Manufacturer Part Number
H335-1-35-0-0-0
Description
Digital Panel Meters HAWK 3.5 DIG METER RED LED
Manufacturer
Simpson
Datasheet

Specifications of H335-1-35-0-0-0

Lead Free Status / RoHS Status
Lead free / RoHS Compliant
• All parameters set from easy to understand
• One, two or four 5-amp relays optional
• Five user-selectable brightness levels
• 1/8 DIN, shallow depth case, 3.24”
• RS485 digital communications optional (H345)
• 12 or 24 DCV power supply output optional
• 4-20mA or 0-10 DCV analog transmission
• NEMA 4X rated front panel
• DIN Rail adapter available
front panel access
optional
For more information, visit www.simpsonelectric.com
(page C1)
Depth
Panel Cutout
ENVIRONMENTAL
Operating Temperature
Storage Temperature
Relative Humidity
Ambient Temperature
Temperature Drift
Warmup Time
Noise Rejection
NMRR
CMRR
A TO D CONVERSION
Technique
Sample Rate
Display Rate
MECHANICAL
Bezel
Weight
Cover
DISPLAY
Type
Quantity
Brightness
Height
Decimal point
Overrange indication
Underrange indication
Alarm Indicators
POWER REQUIREMENTS
AC
DC
ISOLATION
ACCURACY @ 25°C as % of rdg
DC Current
High (5A, 2A)
All Others
DC Volts
High (600 V)
All others
Resistance
All ranges
*AC Current
High (2A, 5A)
All others
*AC Volts
High (600V)
All others
Speci cations
* AC functions measured at 50 Hz, include ± 1 count for each additional
100 Hz above 50 Hz
7-segment, red LED
4 or 5
5 user-selectable levels
0.56" (14.2mm)
4 or 5 position, user programmable
Display flashes “EEEEE” indicating
Maximum Value Exceeded
Display flashes “-EEEE” indicating
Minimum Value Exceeded
4 LED indicators for up to four independ-
ent setpoints
120, 85-250 VAC @ 10VA
0 to 50°C
-10 to +60°C
<80%
25°C
100 ppm/°C
10 minutes
60 dB @ 50-60 Hz
70 dB @ 50-60 Hz
Successive approximation with oversampling
10 conversions per second
User programmable
1-420 updates/min (240 default)
3.9" x 2.0" x 0.52” (99.8mm x 51.9mm x 13.2 mm)
3.24" (82.3 mm)
3.62" x 1.77" (92 mm x 45mm)
10 oz (283.5g)
NEMA 4X Rated front panel
9-36 DCV @ 10VA
250V RMS MAX
0.2% ± 1 count
0.05% ± 1 count
0.1% ± 1 count
0.05% ± 1 count
0.1% ± 2 counts
0.2% ± 2 counts
0.1% ± 2 counts
0.1% ± 1 count
0.05% ± 1 count
4-1/2 digit
0.3% ± 1 count
0.1% ± 1 count
0.2% ± 1 count
0.1% ± 1 count
0.2% ± 1 count
0.1% ± 1 count
0.1% ± 2 counts
0.3% ± 2 counts
0.2% ± 2 counts
3-1/2 digit
more >>

H335-1-35-0-0-0 Summary of contents

Page 1

... RS485 digital communications optional (H345) • DCV power supply output optional • 4-20mA or 0-10 DCV analog transmission optional • NEMA 4X rated front panel • DIN Rail adapter available For more information, visit www.simpsonelectric.com Speci cations DISPLAY Type Quantity Brightness Height ...

Page 2

... Ordering Information Basic Unit Power Supply Function/Range Output Signal Selection Description Basic Unit H335 3-1/2 digit, Red LED H345 4-1/2 digit, Red LED Power Supply 120 ACV (3-1/2 only 85-250 ACV (4-1/2 only) 9-36 DCV 3 85-250 ACV (3-1/2 only) 4 Function/Range 11 200 DCmv ...

Page 3

... Installation and Panel Cutout - H335, H340, H345 3.59” 3.93” Mounting Requirements The Hawk 3 Advanced Digital Controller 1/8 DIN meters require a panel cutout of 1.77” (45mm) high and 3.62” (92 mm wide). To install the Hawk 3 meter into the panel cutout, remove the clips from the side of the meter ...