W2E200-HK38-01 EBM-Papst Industries Inc, W2E200-HK38-01 Datasheet - Page 9

FAN TUBEAXIAL 225X80MM 230VAC

W2E200-HK38-01

Manufacturer Part Number
W2E200-HK38-01
Description
FAN TUBEAXIAL 225X80MM 230VAC
Manufacturer
EBM-Papst Industries Inc
Series
W2E200r
Type
Squarer

Specifications of W2E200-HK38-01

Current Type
AC
Bearing Type
Ball
Weight
4.7 lbs (2.1kg)
Fan Type
Tubeaxial
Size / Dimension
Square - 225mm L x 225mm H x 80mm W
Voltage Rating
230VAC
Power (watts)
80W
Rpm
2800 RPM
Noise
61 dB(A)
Static Pressure
0.381 in H2O (95.0 Pa)
Air Flow
606.0 CFM (17.16m³/min)
Termination
Terminal Block
Product
Fans
External Height
225mm
External Width
225mm
External Depth
80mm
Supply Voltage
230VAC
Flow Rate
606CFM
Noise Rating
61dBA
Power Connection Type
Terminal
Brand/series
W2E200
Dimensions
8.86 x 3.15 "
Direction
Exhaust over Struts
Noise Level
61 dBA
Nominal Speed
2550 to 2800 RPM
Power Rating
64 to 80 W
Power, Rating
80 W
Size
8.86 x 3.15 (225 x 80) In. (mm)
Temperature, Operating, Maximum
+65 °C
Thickness
80 mm
Voltage, Rating
230 VAC
Bearings
Ball
Housing Material
Aluminum Die Cast
Product Length (mm)
260mm
Product Height (mm)
80mm
Product Depth (mm)
260mm
Line Current
0.29/0.35A
Fan Rotation
Counter Clockwise
Flow Rate - Imperial
606CFM
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
381-2442

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
W2E200-HK38-01
Manufacturer:
EBMPAPST
Quantity:
20 000
5.1 Cleaning
5.2 Safety test
Item no.: 10760-5-9970 · Revision status: KM69285 · Print-out on 16/07/2010 · Created by P. Nadig (VM-TDO) · Page 9 of 9
ebm-papst Mulfingen GmbH & Co. KG · Bachmühle 2 · 74673 Mulfingen · Phone: +49 7938 81-0 · Fax: +49 7938 81-110 · www.ebmpapst.com · info1@de.ebmpapst.com
What has to be
tested?
Protective casing
against accidental
contact
Device for damage
Mounting of device
Mounting of
connecting cables
Mounting of protective
earth connection
Insulation of the cables Visual inspection
Weld seams for crack
formation
W2E200-HK38-01
If you have any other problems, contact ebm-papst.
NOTE
Damage to the device during cleaning.
Malfunction possible
Do not clean the device using a water jet or high-pressure
washer.
Do not use any cleaners containing acids,
bases or solvents.
How to test?
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Visual inspection
Frequency
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
at least every 6 months
Operating instructions

Related parts for W2E200-HK38-01