CMA3000-A01 VTI Technologies, CMA3000-A01 Datasheet - Page 2

ACCELEROMETER 3-AXIS ANALOG OUT

CMA3000-A01

Manufacturer Part Number
CMA3000-A01
Description
ACCELEROMETER 3-AXIS ANALOG OUT
Manufacturer
VTI Technologies
Series
CMA3000r
Datasheet

Specifications of CMA3000-A01

Mfg Application Notes
CMA3000 Assembly Instructions C-Code Examples for CMA3000 Accelerometer Sub-1 uA Current Consumption with CMA3000
Axis
X, Y, Z
Acceleration Range
±2g, 8g
Sensitivity
Vdd/24 V/g, Vdd/6 V/g
Voltage - Supply
1.7 V ~ 3.6 V
Output Type
Analog
Bandwidth
120Hz - XZ, 200Hz - Y
Interface
Parallel
Mounting Type
Surface Mount
Package / Case
Surface Mount - Coin Style
For Use With
551-1065 - BOARD PWB ACCEL 3AXIS ANALG OUT
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
551-1063-2
Performance Characteristics Targets
*
**
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)
VTI Technologies Oy
www.vti.fi
Parameter
Vdd
Operating temperature **
Current consumption *
Acceleration range *
Offset *
Offset calibration error *
Offset temperature error **
Sensitivity *
Sensitivity calibration error *
Sensitivity temperature error
**
Non-Linearity **
Cross-Axis sensitivity **
Bandwidth**
Noise **
Output resistance
6)
100% tested in production
Qualified during product validation
The product is factory calibrated at 2.5 V in room temperature.
Typical values are not guaranteed.
Z-axis +1g position. Soldering process can cause offset shift which is typically less than 130 mg. Please see
TN68_CMA3000_Assembly_Instructions for further details.
Offset temperature error = {Vout(0g)-Offset} / Sensitivity [ g ]. Sensitivity = Calibrated sensitivity.
Offset= Calibrated offset.
Sensitivity = {Vout(+1g) - Vout(-1g)}/2 [V/g] .
Sensitivity temperature error = {[Vout(+1g)-Vout(-1g)]/2 - Sensitivity} / Sensitivity x 100% [%].
Sensitivity = Calibrated sensitivity.
Best fit straight line.
The cross-axis sensitivity determines how much acceleration, perpendicular to the measuring axis,
couples to the output. The total cross-axis sensitivity is the geometric sum of the sensitivities of
the two axes which are perpendicular to the measuring axis. The angular alignment error
between X, Y and Z axis is included into the cross axis sensitivity.
Frequency responce -3dB roll off frequency = 1/(2π*32kΩ*C
Average noise/axis over the measurement bandwidth defined as
3)
the measured signal's standard deviation due to noise in x, y and z directions.
10)
5)
9)
7)
8)
3)
4)
Condition
Power down
Active
Range pin set to "1"
Range pin set to "0"
X and Y axis
Z axis
Full scale=2 g,
T=+25 °C
-40 ... +85 °C
X and Z axis
Y axis
Full scale=2 g
Full scale=8 g
T=+25 °C
-40 ... +85 °C
C
С
X and Z axis
Y axis
Full scale=2 g
Full scale=8 g
L
L
=100 nF
=0 nF
Doc. Nr. 8278700A.01
1)
Typical supply range
1.7 – 2.7 V
Min
-100
-40
-10
1.7
30
28
-2
-8
-
-
-
-
-
-
-
-
-
-
Typ
Vdd/24
+sens
Vdd/2
Vdd/2
Vdd/6
±0.02
<0.1
±2.5
180
±25
120
200
300
300
L
2.5
1.5
±1
50
32
), when C
1
-
-
-
-
2)
1
3
(
x n
Max
+100
+10
600
600
2.7
36
85
70
L
2
8
3
2
-
-
-
-
-
≥50 nF.
+
n
y
2
Extended supply
range 2.7 – 3.6 V
Min
+
-40
2.7
28
30
-2
-8
z n
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
) 2
, where nx, ny and nz are
Typ
Vdd/24
Vdd/2
Vdd/2
+sens
Vdd/6
±0.02
±100
<0.1
±2.5
200
±10
120
200
300
300
3.3
1.5
±1
50
32
1
-
-
-
2)
Max
600
600
3.6
85
70
36
2
8
-
-
-
-
-
-
-
-
-
-
-
-
-
-
CMA3000-A01
Units
µg/√Hz
µg/√Hz
mg/°C
% FS
%/°C
V/g
V/g
mg
µA
Hz
Hz
kΩ
°C
%
%
V
V
g
Rev. A.01
2/4

Related parts for CMA3000-A01