MES12-900PC CUI Inc, MES12-900PC Datasheet

ENCODER INTEGRAL 900 CPR

MES12-900PC

Manufacturer Part Number
MES12-900PC
Description
ENCODER INTEGRAL 900 CPR
Manufacturer
CUI Inc
Series
MES12r
Datasheet

Specifications of MES12-900PC

Encoder Type
Optical
Output Type
Quadrature with Index (Incremental)
Pulses Per Revolution
900
Voltage - Supply
5VDC
Actuator Type
2mm Dia Round End
Detent
No
Built In Switch
No
Mounting Type
Chassis Mount
Orientation
Vertical
Termination Style
Cable Leads
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Rotational Life (cycles Min)
-
Other names
102-1033
MES-12-900C
MES-12-900PC
PART NUMBER: MES12
ELECTRICAL SPECIFICATIONS
output waveform
output signals
current consumption
frequency response
output phase difference
supply voltage
output resolution (ppr)
waveform rise/fall time
MECHANICAL SPECIFICATIONS
max shaft load, radial:
starting torque
max rotational speed
shock resistance
vibration proof
weight
cable
ENVIRONMENTAL SPECIFICATIONS
operating temp
storage temp
humidity
ORDERING INSTRUCTIONS
20050 SW 112
100 = 100 PPR
125 = 125 PPR
200 = 200 PPR
256 = 256 PPR
300 = 300 PPR
500 = 500 PPR
60 = 60 PPR
axial:
th
Resolution (PPR):
Ave. Tualatin, Oregon 97062
MES12 - XXXXPX
1000 = 1000 PPR
1500 = 1500 PPR
1800 = 1800 PPR
2000 = 2000 PPR
2048 = 2048 PPR
600 = 600 PPR
900 = 900 PPR
Square wave
A, B, Z phase
≤40 mA
0~100 KHz
A, B phase difference 90° ± 45° (T/4±T/8)
Z phase T±T/2 (see output waveform)
5 V dc ± 10%
60, 100, 125, 200, 256, 300, 360, 500, 600, 900,
1000, 1500, 1800, 2000, 2048
2μ or less (output cable 1m or less)
1.9N (200gf)
1.9N (200gf)
1 x 10
6000 RPM
500m/s
55 Hz, double amplitude 1.5mm, 2 hours each on XYZ
40 g (with 1m cable)
3mm Outside diameter 5-core vinyl wire,
insulated shield cable (length 1m)
-10° to +70° C
-20° to +80° C
RH 35%~90% non collecting
3
phone
phone 503.612.2300 fax
2
N·m (10 gf·cm)
(50G) 3 times each on XYZ
DESCRIPTION: incremental encoder
0.98N (100gf) (1500-2048 ppr)
0.98N (100gf) (1500-2048 ppr)
Output Circuit:
"no entry" = TTL voltage output
C = Open collector output
E = Line driver output
fax 503.612.2383
rev.
page
date
05/2009
1 of 3

Related parts for MES12-900PC

MES12-900PC Summary of contents

Page 1

... Outside diameter 5-core vinyl wire, insulated shield cable (length 1m) -10° to +70° C -20° to +80° 35%~90% non collecting MES12 - XXXXPX 600 = 600 PPR 900 = 900 PPR 1000 = 1000 PPR 1500 = 1500 PPR 1800 = 1800 PPR ...

Page 2

... PART NUMBER: MES12 CIRCUIT CONNECTIONS Voltage Output 2.2kΩ 20mA max CABLE SHIELD Line Drive Output (E) 26C31 CABLE SHIELD OUTPUT WAVEFORM Clockwise rotation viewed from front Phase A Phase B Phase Z th 20050 SW 112 Ave. Tualatin, Oregon 97062 DESCRIPTION: incremental encoder Open Collector Output (C) ...

Page 3

... DESCRIPTION NEW DRAWING Output cable 1 meter 55.00° TOLERANCE: ±0.3mm UNLESS OTHERWISE SPECIFIED 20050 SW 112th Ave. Tualatin, OR 97062 Phone: 503-612-2300 800-275-4899 Fax: 503-612-2383 Website: www.cui.com TITLE: Incremental Encoder PART NO. UNITS: MES12 - - APPROVED BY: DRAWN BY: JMS - - DATE 7/27/2007 RoHS REV [INCHES] SCALE: 2:1 ...

Related keywords