Instruction For Assembly
Adaptor and PG electrical thread backshells
The CLIPPER connector must be equipped with an adaptor in order
to use a PG electrical thread backshell (e.g.: cable clamp or sealing
gland, or flexible conduits system backshells, etc.)
1) Position the O-ring at the bottom of the backnut.
2) Run the backnut around the cable.
3) Unlock the retainer plate.
4) Position the grommet in the thrust ring, resting against the
5) Insert the contacts through the grommet and the retainer plate.
6) Lock the retainer plate.
7) Screw the backshell.
retainer plate.
Grommet Backshell Assembly
1) Manually, fully screw the adaptor on the
2) In
3) Manually, fully screw the PG thread backshell
Note: In the case of an elbow backshell, it is
possible to adjust the position according to the
angle desired.
connector, the hexagonal nut towards the
rear.
O-ring.
of your choice.
the
sealed
Industrial Plastic Connectors
version,
cover
the
23
Heat shrink boot
Shrink sleeve as follows :
1) Use heat gun with an air deflector nozzle.
2) Adjust air deflector opening to accommodate tubing size. Turn
3) Position the air deflector over section of tubing to be shrunk.
4) When tubing begins to shrink, move gun so that air is distributed
5) Move nozzle to adjacent section and shrink in the same manner.
Avoid excessive heat. Direct heat away from connector assembly
to prevent damage.
When the insert is partially filled with contacts, place polarization
contact into selected hole location in the FEMALE INSERT and
push in until seated.
• Polarization contacts are used to provide keying capabilities for
• Polarization contacts are used in the socket-cavities of standard
In order to lock the couple of chosen connectors, you have to let
free the cavity in front of the polarization contact.
To avoid the connection with other connectors, you have to insert a
contact in the cavity in front of the polarization contact.
the CLIPPER series.
plugs and reverse receptacles.
switch ON. Wait until full heat output is reached.
Start at pre-shrunk section and work towards open end.
in a band around the tubing circumference causing it to shrink
evenly around the cable.
Repeat process on section at a time until entire length is shrunk.
for polarizing connector mounting
Instruction
CP16SW9700