CL101030 Souriau Connection Technology, CL101030 Datasheet - Page 22

CABLE CLAMP, SIZE 1

CL101030

Manufacturer Part Number
CL101030
Description
CABLE CLAMP, SIZE 1
Manufacturer
Souriau Connection Technology
Series
Clipperr
Datasheet

Specifications of CL101030

Connector Type
Clamp / Strain Relief
Connector Shell Size
1
Strain Relief Material
Thermoplastic
Cable Diameter Max
3mm
Svhc
No SVHC (15-Dec-2010)
Shell Plating
Gold
Cable Diameter Min
2mm
Colour
Black
Rohs Compliant
Yes
For Use With
Industrial Plastic Connectors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Clipper
Instruction For Assembly
Insertion and extraction of contacts
Single wires
Contact insertion and extraction is performed without a tool thanks to te retainer plate system.
Insertion
Special case of jacketed cables
1) Locate the first contact and the corresponding cavity.
2) The wire should described a buckle as describe below.
3) Unlock the retainer plate as described above.
4) Fully insert the wired contact in the cavity.
5) Respect the same procedure for the other contacts
6) Once again squeeze the retainer plate flaps and push forwards : the
plate is then locked
1) With the thumb and index finger, squeeze the
2) Fully insert the wired contact in the cavity.
3) Repeat the same procedure for the other contacts.
4) Once again squeeze the retainer plate flaps and
5) The plate can only be pushed backed if the
retainer plate flaps and pull backwards : the plate is
then in
the unlocked position.
push forwards: the plate is then locked and retains
the contacts (90 N of retention force for contacts of
1.6 mm dia.)
contacts are correctly engaged (backup security)
Industrial Plastic Connectors
22
Extraction
Special case of jacketed cables
7) Manually fully screw the adaptor and the backshell on the connector.
Caution : In the sealed version don’t forget the O-ring.
8) Push forwards the cable of 10 mm in the backshell.
9) Fully screw on the backshell with a wrench while keeping the adaptor
Note : The plate can only be pushed back if the contacts are correctly
engaged (backup- security)
with another wrench.
1) With the thumb and index finger, squeeze the
2) Pull the contact wire: the the contact comes out of
3) Repeat the same procedure for the other contacts.
retainer plate flaps and pull backwards : the plate is
then in
the unlocked position.
the cavity.

Related parts for CL101030