Specifications of LM92CIM

Sensing Accuracy Range
± 0.33°C
Supply Current
350µA
Supply Voltage Range
2.7V To 5.5V
Sensor Case Style
SOIC
No. Of Pins
8
Svhc
No SVHC (15-Dec-2010)
Operating Temperature Max
150°C
Ic Output Type
Open Drain
Temperature Sensing Range
-55°C To +150°C
Resolution (bits)
13bit
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
LM92CIM
Manufacturer:
ns
Quantity:
170
Part Number:
LM92CIM
Manufacturer:
NS
Quantity:
25
Part Number:
LM92CIM
Manufacturer:
NSC
Quantity:
9
Part Number:
LM92CIM
Manufacturer:
NS
Quantity:
1 000
Part Number:
LM92CIM
Manufacturer:
NS/国半
Quantity:
20 000
Part Number:
LM92CIM/NOPB
Quantity:
570
Part Number:
LM92CIM/NOPB
Manufacturer:
NS
Quantity:
10 178
Part Number:
LM92CIMX
Manufacturer:
NS/国半
Quantity:
20 000
Company:
Part Number:
LM92CIMX
Quantity:
25 000
Part Number:
LM92CIMX/NOPB
0
Company:
Part Number:
LM92CIMX/NOPB
Quantity:
10 000
www.national.com
Conditions
T
T
T
T
T
T
T
T
T
Note 9: The limits found in the following table supersede the limits shown in the Electrical Characteristics Table. The Accuracy specification includes errors due to
linearity, offset and gain. The accuracy specification includes effects of self heating with negligible digital output loading. Pull-up resistors should be maximized (10k
typical recommended), so that self heating due to digital output loading is negligible.
Limits at intermediate temperatures can be calculated using a straight line interpolation as shown in the following graphs:
Note 10: 12 bits + sign, two’s complement
Note 11: Linearity Error is defined as the worse case difference of an actual reading to that of a calculated reading derived from the straight line whose endpoints
are measured at 30˚C and 125˚C for the range of 30˚C to 125˚C or whose endpoints are measured at 30˚C and −25˚C for the range of 30˚C to −25˚.
Note 12: Offset Error calibration should be done at 30˚C. The residual error of the transfer function is then equivalent to the Accuracy Limit minus the Offset Limit.
This does not take into account the power supply sensitivity of the offset error. Nor, does it take into account the error introduced by the calibration system used.
A
A
A
A
A
A
A
A
A
= −25˚C
= −10˚C
= 0˚C
= 10˚C
= 30˚C
= 50˚C
= 85˚C
= 125˚C
= 150˚C
Temperature Accuracy Parameter Limits
+V
−1.35/+1.50
±
−0.80/+0.75
−0.60/+0.50
−0.43/+0.33
−0.60/+0.50
−1.10/+0.85
−1.60/+1.25
±
1.00
1.90
S
=2.7V
+V
−1.25/+1.50
−0.90/+1.00
−0.70/+0.75
±
±
±
−1.00/+0.85
−1.50/+1.25
−1.75/+1.50
0.50
0.33
0.50
S
Accuracy vs Temperature with +V
=3.3V
Accuracy vs Temperature with +V
+V
−1.25/+1.50
−0.90/+1.00
−0.70/+0.75
±
±
±
−1.00/+0.85
±
±
0.50
0.33
0.50
1.25
1.50
S
=4V
6
+V
−1.05/+1.70
−0.70/+1.20
−0.50/+0.95
−0.30/+0.70
−0.13/+0.53
−0.30/+0.70
−0.80/+1.05
−1.05/+1.45
−1.30/+1.70
s
s
S
= 3.3V
=5V
= 5V
10105121
10105120
+V
−1.05/+1.80
−0.70/+1.30
−0.50/+1.05
−0.30/+0.80
−0.13/+0.63
−0.30/+0.80
−0.80/+1.15
−1.05/+1.55
−1.30/+1.80
S
=5.5V
Units
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)
˚C (max)