8910DPA43V14 SQUARE D, 8910DPA43V14 Datasheet - Page 17

CONTACTOR, 3PST-NO, 24VAC, 40A, PANEL

8910DPA43V14

Manufacturer Part Number
8910DPA43V14
Description
CONTACTOR, 3PST-NO, 24VAC, 40A, PANEL
Manufacturer
SQUARE D
Type
DPr
Datasheets

Specifications of 8910DPA43V14

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
Panel
Coil Voltage Vac Nom
24V
Relay Terminals
Screw
Contact Voltage Ac Nom
600V
Contact Current Max
40A
Mounting Type
Panel
Contact Form
3PST-NO
Current, Rating
40 A
Function
Contactor
Horsepower, Max, 1 Phase, At 115 V
3 @ 115 VAC, 7.5 @ 230 VAC
Horsepower, Max, 3 Phase, At 230 V
10 @ 230VAC, 20 @ 460VAC
Number Of Poles
3
Relay Type
Electro Mechanical
Voltage, Coil
24 VAC
Enclosure Type
Open
Maximum Voltage Rating
600 VAC
Phase
1-Phase
Operating Voltage
600VAC
Switching Power Ac1
7.5hp
Switching Power Ac3
20hp
Switching Current Ac1
50A
Switching Current Ac3
40A
Load Current Inductive
40A
Load Current Resistive
50A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
Melting Alloy
Overload Relay
Jumper Strap Kits
Disconnecting Means, Provided
1
by User, or with Controller
L1
Class 9998 Type SO1
T1
L1
T1
5/98
Motor
L2
T2
L2
T2
Three Phase Starter
Wired to Control a
Single Phase Motor
T3
L3
Contact Units for Melting Alloy Type Overload Relays
One normally closed contact, Class 9998 Type SO1, is provided in each overload relay block on
Class 8911 Type DPS starters. Contact modules can be easily replaced and are identified in the table
below. Isolated overload relay alarm circuit contacts are available as an optional feature. A pilot light or
alarm bell can be wired in series with this contact to indicate that the overload relay has tripped.
Melting Alloy Overload Relay Jumper Strap Kits
Jumper strap kits are for use on three-phase magnetic starters with melting alloy overload relays only,
where a three-phase starter is used to control a single-phase motor. These kits will include two jumper
straps, a wiring diagram showing how to wire a three-phase starter to control a single-phase motor, and
single-phase (one thermal unit) selection tables.
q Refer to Page 11-131 for contact ratings.
20 A through 90 A
Class
Ampere
ALL
Size
Magnetic Starter
Type
DPS
© 1998 Square D All Rights Reserved
20 A through 50 A
60 A through 90 A
Ampere Size
Standard N.C. contact unit ....................................................................
N.O. isolated alarm contact and standard N.C. overload contact..........
For Starter
Descriptionq
Starter Accessories — Class 9998
Type
DPS
DPS
Class 9998 Type SO1
Class 9998 Type SO4
Kit Type Number
Parts Kit
Number
Class 9998
SO31
SO32
17