CA3KN40BD TELEMECANIQUE, CA3KN40BD Datasheet - Page 3

Control Contactor

CA3KN40BD

Manufacturer Part Number
CA3KN40BD
Description
Control Contactor
Manufacturer
TELEMECANIQUE
Datasheet

Specifications of CA3KN40BD

Contact Configuration
4NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Coil Power Vdc
1.5W
Length/height, External
58mm
Nom Operating Power
3W
External Width
45mm
External Depth
57mm
Operating Voltage
600VAC
Load Current Inductive
10A
Load Current Resistive
10A
No. Of Poles
4
6.2
6
References
CA2-KN403pp
CA3-KN407pp
Characteristics:
pages 6/8 and 6/9
CA2-KN40pp
6/10
Dimensions:
page 6/14
- Mounted on 35 mm 7 rail or Ø 4 screw fixing.
- Screws in open “ready-to-tighten” position.
Control circuit
Consumption
Screw clamp connections
4.5 VA
Spring terminal connections
4.5 VA
Faston connectors, 1 x 6.35 or 2 x 2.8
4.5 VA
Solder pins for printed circuit boards
4.5 VA
- Mounted on 35 mm 7 rails or Ø 4 screw connections.
- Screws in open “ready-to-tighten” position.
Screw clamp connections
3 W
Spring terminal connections
3 W
Faston connectors, 1 x 6.35 or 2 x 2.8
3 W
Solder pins for printed circuit boards
3 W
(1) Standard control circuit voltages (for other voltages, please call our Customer information centre on 0870 608 8 608).
Control relays CA2-K (0.8...1.15 Uc) (0.85...1.1 Uc)
Volts a
50/60 Hz
Code
Up to and including 240 V, coil with integral suppression device available: add 2 to the code required. Example: J72
Control relays CA3-K (0.8...1.15 Uc)
Volts c
Code
Coil with integral suppression device available: add 3 to the code required. Example: JD3.
(2) When connecting an electronic sensor or timer in series with the coil of the control relay, select a 20 V coil (a control
voltage code Z7, c control circuit voltage code ZD) so as to compensate for the incurred voltage drop.
Mini-control relays for a.c. control circuit
Mini-control relays for d.c. control circuit
12 20
JD ZD BD
12 20
J7 Z7
Control relays
K mini-control relays
For control circuit: a.c. or d.c.
Schemes:
page 6/15
24(2) 36 48
24(2) 36 42
B7
CD ED ND SD KD
C7 D7 E7 F7
60
48
72
110 115 127 220/ 230 230/ 380/ 400 400/ 440 500 660/
100 110 125 200 220 230
FE7 FC7 M7
Auxiliary
contacts
4
3
2
4
3
2
4
3
2
4
3
2
4
3
2
4
3
2
4
3
2
4
3
2
FD
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
GD
230
LD
P7
Basic reference.
Complete with code
indicating control
circuit voltage (1)
CA2-KN40 pp
CA2-KN31 pp
CA2-KN22 pp
CA2-KN403 p p p p p p p p
CA2-KN313 p p p p p p p p
CA2-KN223 p p p p p p p p
CA2-KN407 pp
CA2-KN317 pp
CA2-KN227 pp
CA2-KN405 pp
CA2-KN315 pp
CA2-KN225 pp
CA3-KN40 pp
CA3-KN31 pp
CA3-KN22 pp
CA3-KN403 pp
CA3-KN313 pp
CA3-KN223 pp
CA3-KN407 pp
CA3-KN317 pp
CA3-KN227 pp
CA3-KN405 pp
CA3-KN315 pp
CA3-KN225 pp
MD
240 400
U7
MPD MUD UD
Q7
240 250
V7
Schneider Electric
415
N7
a
a
a
a
c c c c
R7
or
S7
Weignt
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.180
0.210
0.210
0.210
0.225
0.225
0.225
0.225
0.225
0.225
0.225
0.225
0.225
0.255
0.255
0.255
690
Y7
kg

Related parts for CA3KN40BD