AF16-22-00-13 ABB, AF16-22-00-13 Datasheet - Page 6

no-image

AF16-22-00-13

Manufacturer Part Number
AF16-22-00-13
Description
CONTACTOR,4P,250V,30A
Manufacturer
ABB
Datasheet

Specifications of AF16-22-00-13

Operating Voltage
250V
Switching Current Ac1
30A
No. Of Poles
4
Contacts
2NO / 2NC
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
250V
Coil Voltage Vdc Nom
250V
Svhc
No SVHC (18-Jun-2010)
Contact
RoHS Compliant
Contact Configuration
2NO / 2NC
Rohs Compliant
Yes
Coil Type
AC/DC
AF09 and AF16 4-pole Contactors
Technical Data
General Technical Data
Contactor types
Rated insulation voltage U
Rated impulse withstand voltage U
Electromagnetic compatibility
Ambient air temperature
Climatic withstand
Operating altitude
Mechanical durability
Shock withstand
Mounting position 1
Vibration withstand
acc. to IEC 60068-2-6
Magnet System Characteristics
Contactor types
Coil operating limits
acc. to IEC 60947-4-1
AC control voltage
50/60 Hz
DC control voltage
PLC-Output control
Drop-out voltage in % of U
Voltage sag immunity
Dips withstand
-20 °C ≤ θ ≤ +60 °C
Operating time
Mounting Characteristics
Contactor types
Mounting positions
Mounting distances
Fixing
A
between coil energization and:
between coil de-energization and:
on rail according to IEC 60715, EN 60715
by screws (not supplied)
acc. to IEC 60947-4-1
acc. to UL / CSA
Operation in free air
Storage
Number of operating cycles
Max. switching frequency
A
B1
(level 0% according to IEC 61000-4-11)
acc. IEC 60068-2-27 and EN 60068-2-27
Rated control circuit voltage U
Coil consumption
Rated control circuit voltage U
Coil consumption
C1
C2
according to SEMI F47-0706
close to contactor
B2
i
c
min.
Closed or open
position
imp
Average holding value
Average holding value
N.C. contact opening
N.O. contact opening
Average pull-in value
Average pull-in value
N.O. contact closing
N.C. contact closing
c
c
Shock direction
DC supply
AC supply
B1
B2
C1
C2
A
AF09
690 V
600 V
6 kV
Devices complying with IEC 60947-1 / EN 60947-1 - Environment A
-40 ... +70 °C
-60 ... +80 °C
Category B according to IEC 60947-1 Annex Q
≤ 3000 m
10 millions operating cycles
3600 cycles/h
1/2 sinusoidal shock for 11 ms: no change in contact position
30 g
25 g Closed position / 5 g Open position
15 g
25 g
25 g
5 ... 300 Hz
4 g Closed position / 2 g Open position
AF09
at θ ≤ 60 °C 0.85 x U
at θ ≤ 70 °C 0.85 x U
at θ ≤ 60 °C 0.85 x U
at θ ≤ 70 °C (AF) 0.85 x U
24 ... 500 V AC
(AF) 50 VA - (AF..Z) 16 VA
(AF) 2.2 VA / 2 W - (AF..Z) 1.7 VA / 1.5 W
12 ... 500 V DC
(AF) 50 W - (AF..Z) 12 ... 16 W
(AF) 2 W - (AF..Z) 1.7 W
(AF..Z) ≥ 500 mA 24 V DC
≤ 60 % U
(AF..Z) conditions of use on request
(AF..Z) 22 ms average for U
40 ... 95 ms
38 ... 90 ms
11 ... 95 ms
13 ... 98 ms
AF09
Max. add-on N.C. auxiliary contacts: see accessory fitting details for a 4-pole contactor
AF09 or AF16
The contactors can be assembled side by side.
35 x 7.5 mm or 35 x 15 mm
2 x M4 screws placed diagonally
Pos
. 4
Pos
c
. 2
Pos. 1
min
Pos. 3
+30°
c
c
c
min ... 1.1 x U
min ... 1.1 x U
min ... U
c
Pos. 1 ± 30°
c
min ... U
-30°
= 24 ... 250 V 50/60Hz
c
max
c
c
max - (AF..Z) 0.85 x U
c
max
max
AF16
AF16
AF16
Pos. 5
c
min ... 1.1 x U
Catalogue Page
c
1SBC 101 109 S0201
max
ABB | 7

Related parts for AF16-22-00-13