LC1D80U7 SQUARE D, LC1D80U7 Datasheet - Page 2

CONTACTOR 3PST-NO 240VAC, 125A, DIN RAIL

LC1D80U7

Manufacturer Part Number
LC1D80U7
Description
CONTACTOR 3PST-NO 240VAC, 125A, DIN RAIL
Manufacturer
SQUARE D
Datasheet

Specifications of LC1D80U7

No. Of Poles
3
Contact Configuration
3PST-NO
Relay Mounting
DIN Rail
Coil Voltage Vac Nom
240V
Relay Terminals
Screw Clamp
Nom Operating Power
45kW
Contact Voltage Ac Nom
1kV
Operating Voltage
600VAC
Switching Power Ac1
15hp
Switching Power Ac3
60hp
Switching Current Ac1
125A
Switching Current Ac3
80A
Load Current Inductive
80A
Load Current Resistive
125A
Rohs Compliant
No
Lead Free Status / RoHS Status
Contains lead / RoHS non-compliant
2
Main
Range of product
Product or component
type
Device short name
Contactor application
Utilisation category
Poles description
Power pole contact
composition
[Ue] rated operational
voltage
[Ie] rated operational
current
Motor power kW
Motor power HP (UL /
CSA)
Control circuit type
Control circuit voltage
Auxiliary contact com-
position
[Uimp] rated impulse
withstand voltage
Overvoltage category
[Ith] conventional free
air thermal current
Irms rated making ca-
pacity
Rated breaking capac-
ity
[Icw] rated short-time
withstand current
Associated fuse rating
Average impedance
TeSys D
Contactor
LC1D
Motor control
Resistive load
AC-1
AC-3
3P
3 NO
<= 1000 V AC 25...400 Hz for power circuit
<= 690 V DC for power circuit
125 A (<= 60 °C) at <= 440 V AC AC-1 for power cir-
cuit
80 A (<= 60 °C) at <= 440 V AC AC-3 for power cir-
cuit
45 kW at 1000 V AC 50/60 Hz
45 kW at 660...690 V AC 50/60 Hz
55 kW at 500 V AC 50/60 Hz
45 kW at 415...440 V AC 50/60 Hz
37 kW at 380...400 V AC 50/60 Hz
22 kW at 220...230 V AC 50/60 Hz
60 hp at 575/600 V AC 50/60 Hz for 3 phases mo-
tors
60 hp at 460/480 V AC 50/60 Hz for 3 phases mo-
tors
25 hp at 230/240 V AC 50/60 Hz for 3 phases mo-
tors
15 hp at 230/240 V AC 50/60 Hz for 1 phase motors
7.5 hp at 115 V AC 50/60 Hz for 1 phase motors
20 hp at 200/208 V AC 50/60 Hz for 3 phases mo-
tors
AC 50/60 Hz
240 V AC 50/60 Hz
1 NO + 1 NC
8 kV conforming to IEC 60947
III
125 A at <= 60 °C for power circuit
10 A at <= 60 °C for signalling circuit
1100 A at 440 V for power circuit conforming to IEC
60947
250 A DC for signalling circuit conforming to IEC
60947-5-1
140 A AC for signalling circuit conforming to IEC
60947-5-1
1100 A at 440 V for power circuit conforming to IEC
60947
320 A <= 40 °C 1 min power circuit
135 A <= 40 °C 10 min power circuit
990 A <= 40 °C 1 s power circuit
640 A <= 40 °C 10 s power circuit
140 A 100 ms signalling circuit
120 A 500 ms signalling circuit
100 A 1 s signalling circuit
160 A gG at <= 690 V coordination type 2 for power
circuit
200 A gG at <= 690 V coordination type 1 for power
circuit
10 A gG for signalling circuit conforming to IEC
60947-5-1
0.8 mOhm at 50 Hz - Ith 125 A for power circuit

Related parts for LC1D80U7