XTCE065D00TD EATON CUTLER HAMMER, XTCE065D00TD Datasheet - Page 79

CONTACTOR, 24VDC, 65A, DIN RAIL

XTCE065D00TD

Manufacturer Part Number
XTCE065D00TD
Description
CONTACTOR, 24VDC, 65A, DIN RAIL
Manufacturer
EATON CUTLER HAMMER
Datasheet

Specifications of XTCE065D00TD

No. Of Poles
3
Contact Configuration
SPST-NO
Relay Mounting
DIN Rail
Coil Voltage Vdc Nom
24V
Relay Terminals
Screw Clamp
Coil Voltage Dc Min
24V
Nom Operating Power
35kW
Operating Voltage
690VAC
Switching Power Ac1
15hp
Switching Power Ac3
60hp
Switching Current Ac1
98A
Switching Current Ac3
65A
Load Current Inductive
65A
Load Current Resistive
98A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
March 2009
Auxiliary Contacts
Table 34-117. Auxiliary Contacts Technical Data and Specifications
Table 34-118. Parallel Link Technical Data and Specifications
Table 34-119. Cable Terminal Block, Flat Cable Terminal Technical Data and Specifications
CA08102001E
Description
Interlocked opposing contacts with an auxiliary
contact module (to IEC 60947-5 -1 Annex L)
Break contact (not late-break contact)
suitable as a mirror contact
(to IEC/EN 60947-4 -1 Annex F)
Rated impulse withstand voltage, (U imp ) V AC
Overvoltage category / pollution degree
Rated insulation voltage, (U i ) V AC
Rated operational voltage, (U e ) V AC
Safe isolation to VDE 0106 Part 101 and
Part 101(A) in V AC
Rated Operational Current, l e
Conventional thermal current, I th
Control circuit reliability
(at U e = 24 V DC, U min = 17 V, I min = 5.4 mA)
Component Lifespan, Operations x 10
at U e = 230V, AC-15, 3A
Short-circuit rating without welding
Description
Terminal Capacity
Tightening Torque (Nm)
Tools
Conventional Thermal Current
Description
Terminal Capacity
Between coil and auxiliary contacts
Between the auxiliary contacts
AC-15
DC-3 L/R ≤5 mS
Maximum fuse, gG/gL
Solid (mm
Flexible with ferrule (mm
Stranded (mm
Flat conductor —
number of segments x width x thickness (mm)
Pozidriv screwdriver
Hexagon socket head spanner — SW (mm)
3-Pole (I th ) A
4-Pole (I th ) A
Stranded (mm
Stranded (AWG)
Flat conductor —
number of segments x width x thickness (mm)
Making and breaking conditions to DC-13, time L/R contact as stated.
See fuses overlay for time/current characteristic (on request).
Conventional thermal current (I th ) of XTCEXSCC_ is 10A.
230V
380/415V
500V
110V
220V
24V
60V
2
)
2
2
)
)
2
)
6
XTCE007B…–
XTCE032C
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
4A
1.5A
10A
6A
3A
1A
16A
1.3
10A
XTCEXPLKB
1 – 16
1 x (0.5 – 25)
2 x (0.5 – 16)
1 x (0.5 – 25)
2 x (0.5 – 16)
6 x 9 x 0.8
4
Size 2
50
60
XTCEXTLA400
1 x (120 – 300)
2 x (70 – 240)
1 x (1/0 – 600 MCM)
2 x (1/0 – 500 MCM)
1 x (10 x 16 x 0.8)
2 x (20 x 24 x 0.5)
2 x (11 x 21 x 1)
For more information visit: www.eaton.com
IEC Contactors & Starters
XT IEC Power Control
Contactors and Starters
XTCEXFAC…
XTCEXFATC...
Yes
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
3A
10A
6A
3A
1A
16A
1.3
10A
XTECXPLKC
16
1 x (16 – 35)
1 x (16 – 50)
4
Size 2
100
XTCEXPLK185
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
<10
-8
, < one failure at 100 million operations
XTCEXFCC…
XTCEXSCC...
Yes
XTCE007B… –
XTCE032C
6000
III/3
690
500
400
400
6A
4A
1.5A
10A
6A
3A
1A
16A
1.3
10A
XTCEXPLKD
16
1 x (16 – 120)
1 x (16 – 120)
14
5
180
XTCEXTFB650
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
XTCEXFAG…
Yes
XTCE040D… –
XTCE065D…
6000
III/3
690
500
440
440
6A
4A
1.5A
10A
6A
3A
1A
10A
1.3
16A
XTCEXPLKG
1 x (35 – 300)
2 x (35 – 120)
2 x (11 x 21 x 1)
6
400
XTCEXTFB820
1 x (6 x 16 x 0.8)
2 x (10 x 40 x 1)
2 x (20 x 40 x 0.5)
XTCEXSBLN…
XTCEXSBN…
XTCEXSBNC...
XTCEXSCN…
XTCEXSCNC…
Yes
XTCE040D… –
XTCE065D…
XTCE185L… –
XTCEC10N…
6000
500
440
440
6A
4A
1.5A
10A
6A
3A
1A
10A
1.3
XTCEXPLK185
1 x (6 x 16 x 0.8)
2 x (20 x 32 x 0.5)
2 x (11 x 21 x 1)
III/3
690
16A
34-79
34

Related parts for XTCE065D00TD