V23201C1001A502 Tyco Electronics, V23201C1001A502 Datasheet

no-image

V23201C1001A502

Manufacturer Part Number
V23201C1001A502
Description
RELAY, SPST, NO, 12V
Manufacturer
Tyco Electronics
Datasheet

Specifications of V23201C1001A502

Coil Voltage Vdc Nom
12V
Contact Current Max
33A
Contact Voltage Dc Nom
12V
Coil Resistance
176ohm
Relay Mounting
PC Board
External Width
18.3mm
External Depth
16mm
Contact Configuration
SPST
Contact
RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
V23201C1001A502
Manufacturer:
TE
Quantity:
12 000
Features
– 60% volume reduced
– PCB area requirements
– Size optimized to
– Limiting continuous
– Maximum switch on
– Increased ambient
– Design allows highest
– High shock and vibration
– Wave (THT) and reflow
– For latching (bistable)
Typical Applications
– ABS control
– Blower fans
– Cooling fan
– Engine control
– Fuel pump
– Glow plug
– Hazard warning signal
– Switched power supply
Please contact Tyco Electronics for
relay application support.
134
Disclaimer
All technical performance data apply to the relay as such, specific conditions of the individual application are not considered. Please always check the suitability of the
relay for your intended purpose. We do not assume any responsibility or liability for not complying herewith. We recommend to complete our questionnaire and to request
our technical service. Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification.
All rights of Tyco Electronics are reserved.
Power K at increased
performance
minimized by 50% to
only 293 mm
L x W x H (mm)
18.3 x 16 x 15.9
current 40 A
current 200 A
temperature 105°C
reliability
resistance
(THR/pin-in-paste)
solderable versions
version refer to
Power Relay PK2 Latching
2
PCB Relays
Single Relays
Power Relay PK2 (THT – THR)
Design
– ELV/RoHS/WEEE compliant
– THT: sealed type washable
– THR: sealed type open vent hole
Weight
Approx. 11 g (0.39 oz.)
Nominal Voltage
12 V
All specifications subject to change. Consult Tyco Electronics for latest specifications.
Terminals
PCB terminals for assembly on
printed circuit boards
Conditions
All parametric, environmental and
endurance tests are performed
according to EIA Standard RS-407-A
at standard test conditions unless
otherwise noted:
23°C ambient temperature,
20 - 50% RH, 998.9 ±33.9 hPa.
For general storage and processing
recommendations please refer to our
Application Notes and especially to
Storage in the “Glossary” page 23 or
at http://relays.tycoelectronics.com/
appnotes/
Catalog 1308028-2
Revised 3-2008
201_C-R_3D3

Related parts for V23201C1001A502

V23201C1001A502 Summary of contents

Page 1

... Any responsibility for the application of the product remains with the customer only. All specifications are subject to change without notification. All rights of Tyco Electronics are reserved. 134 All specifications subject to change. Consult Tyco Electronics for latest specifications. Terminals Conditions ...

Page 2

... Power Relay PK2 (THT – THR) Dimensional Drawing *) Additional tin tops max View of the Terminals (bottom view) Remark: Positional tolerances according to DIN EN ISO 5458 **) without tinning (hop dip) All specifications subject to change. Consult Tyco Electronics for latest specifications. 201C_DD1 Catalog 1308028-2 Revised 3-2008 201C_DD2 201C_VT1 ...

Page 3

... The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V load voltages. 3) See chapter Diagnostics of Relays in our Application Notes page 31 or consult the internet at http://relays.tycoelectronics.com/appnotes/ Load Limit Curve 136 All specifications subject to change. Consult Tyco Electronics for latest specifications. Resistive/inductive/capacitive load 1 Make contact/ 1 Form A 5 (+) ...

Page 4

... A low resistive suppression device in parallel to the relay coil increases the release time and reduces the lifetime caused by increased erosion and/or higher risk of contact tack welding (monostable version only). Operating Voltage Range All specifications subject to change. Consult Tyco Electronics for latest specifications. Catalog 1308028 ...

Page 5

... Allowable overdrive is stated with no load applied and minimum coil resistance. Standard Delivery Packs (orders in multiples of delivery pack) PK2 – THT/THR: 600 pieces 138 All specifications subject to change. Consult Tyco Electronics for latest specifications. Refer to Storage in the “Glossary” catalog page 23 or http://relays.tycoelectronics.com/appnotes/ Testing as per IEC 68-2-1 IEC 68-2-2 ...

Related keywords