Coil Voltage Vac Nom
230V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Max
30V
Coil Resistance
224ohm
Relay Mounting
Plug-In
External Width
12.5mm
External Depth
35.4mm
Svhc
No
Contact Configuration
SPCO
External Height
28.8mm
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Contacts
Materials
Max. switching current
Peak inrush current (10 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
Max. AC resistive load (Table 8)
Max. DC load
Standard types, DC
DC 6, 12, 24, 48
Free wheeling diode
Free wheeling and polarity C3-S14F / ... V
Note: The connection of diodes to the coil
will increase the initial drop-out time.
LED not available
Specifications
Nominal coil power
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
C3-S14..
6A / 250V AC1
Dimensions (mm)
Operating range: 0,8 ... 2,5 x Un
One change-over contact, 6 A
12 14
5
.
11
6
7
Sensitive, 250 mW
10
A2
A1 (+)
2
6A @ 30V DC1
code 4 (standard)
C3-S14
C3-S14D / ... V
A2
35
6
See Table 9
250 mW
A1
1,2 KVA
/ ... V
18 ms.
10 ms.
2,5 KV
2,5 KV
250 V
400 V
250V
15 A
6 A
MRC 11 PIN SENSITIVE COIL
(WIDE VOLTAGE TOLERANCE)
• Lockable test button
• Marking label on relay
• Colour coded test button
• Coil voltage marked on top of relay
• Label carries full technical information
• CE marked
KVA 0
Contacts
Materials
Max. switching current
Peak inrush current (10 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
Max. AC resistive load (Table 8)
Max. DC load
Standard types, DC
DC 6, 12, 24, 48, 60
Free wheeling diode
Free wheeling and polarity C3-E24F / ... V
Note: The connection of diodes to the coil
will increase the initial drop-out time.
LED not available
Specifications
Nominal coil power
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
C3-E24...
6A / 250V AC1
0,1
10
1
Table 8
Types C3-S14, C3-E24, C3-N34
Operating range: 0,8 ... 1,7 x Un
Two change-over contacts, 6 A
12 14
4
11
1
3
0,5
Electrical life (ops x 10
22 24
8
47
11
21
9
Sensitive, 500 mW
6A @ 30V DC1
code 4 (standard)
1
C3-E24
C3-E24D / ... V
10
A1 (+)
A2
2
See Table 9
AC1
1,2 KVA
500 mW
1,5
/ ... V
18 ms.
10 ms.
2,5 KV
2,5 KV
250 V
400 V
6
250V
15 A
)
6 A
Volts 25
Contacts
Materials
Max. switching current
Peak inrush current (10 ms)
Max. switching voltage, (pollution 3)
Max. switching voltage, (pollution 2)
Max. AC resistive load (Table 8)
Max. DC load
Standard types, DC
DC 6, 12, 24, 48, 60, 110
Free wheeling diode
Free wheeling and polarity C3-N34F / ... V
Note: The connection of diodes to the coil
will increase the initial drop-out time.
LED not available
Specifications
Nominal coil power
Operate time
Release time
Isolation: EN60947 pollution 3, Gr C
Dielectric strength, contacts / coil
Dielectric strength, pole / pole
0,1
10
C3-N34...
6A / 250V AC1
1
Table 9
Types C3-S14, C3-E24, C3-N34
Operating range: 0,8 ... 1,4 x Un
Three change-over contacts, 6 A
12 14
4
50
11
1
3
22 24
100
5
21
6
7
32 34
Sensitive, 800 mW
8
11
150
31
6A @ 30V DC1
9
Max. DC load
code 4 (standard)
C3-N34 / ... V
C3-N34D / ... V
RELAYS
DC1
10
A1 (+)
A2
200
2
See Table 9
1,2 KVA
800 mW
18 ms.
10 ms.
2,5 KV
2,5 KV
250 V
400 V
250V
15 A
6 A

Related parts for C10A10X230A