Specifications of DUA01CB23500V

Contact Configuration
SPDT
Power Consumption
4VA
Supply Voltage Max
230VAC
Relay Mounting
DIN Rail
Control Voltage Type
AC
Control Voltage
500V
Leaded Process Compatible
Yes
Carry Current
8A
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
DUA01CB23500V
Manufacturer:
Carlo gavazzi
Quantity:
500
2
DUA01, PUA01
Supply Specifications
Power supply
Dielectric voltage
Rated operational power
Mode of Operation
DUA01 and PUA01 monitor
both AC and DC over voltage.
When connected with MI or
MP
(using the 0.4 - 4 V
they can monitor 1-phase or
3-phase AC currents up to
500 A.
Example 1
(connection between termi-
nals Z1, Y1 or 8, 9 - latch
function enabled)
The relay operates and latch-
es
when the measured value
exceeds the set level. Pro-
vided that the voltage has
dropped min. 4% below the
set point (see hysteresis),
the relay releases when the
interconnection between ter-
minals Z1, Y1 or 8, 9 is inter-
rupted or the power supply
is interrupted as well.
Rated operational voltage
through terminals:
AC
DC
A1, A2 or A3, A2
2, 10 or 11, 10
Supply to input
Supply to output
Input to output
in
current
operating
transformer
p
position
(DUA01)
(PUA01)
range)
B48:
B23:
724:
748:
Example 2 (MI CT)
(no connection between ter-
minals Z1, Y1 or 8, 9)
The relay operates when the
current flowing through the
CT exceeds the set level. It
releases when the current
drops min. 4% below the set
level
when power supply is inter-
rupted.
Example 3 (MP CT)
(no connection between ter-
minals Z1, Y1 or 8, 9 - latch
function disabled)
The relay operates when the
maximum
through the CT exceeds the
set level. It releases when
the maximum current drops
min. 4% below the set level
(see hysteresis) or when
power supply is interrupted.
Overvoltage cat. III
(IEC 60664, IEC 60038)
24 VDC ± 20%, insulated
48 VDC ± 20%, insulated
24/48 VAC ± 15%
45 to 65 Hz, insulated
115/230 VAC ± 15%
45 to 65 Hz, insulated
DC supply
2 kV
4 kV
4 kV
4 VA
2 W
(see
current
hysteresis)
4 kV
4 kV
4 kV
AC supply
flowing
or
Reaction time
Accuracy
Indication for
Environment
Housing dimensions
Weight
Screw terminals
Approvals
CE Marking
EMC
Range - Level Setting
Adjust the measuring range
setting the DIP switches 1 to
4 as shown below.
To access the DIP switches
open the grey plastic cover
using
shown below.
General Specifications
Alarm ON delay
Alarm OFF delay
Temperature drift
Repeatability
Power supply ON
Output relay ON
Degree of protection
Pollution degree
Operating temperature
Storage temperature
DIN-rail version
Plug-in version
Tightening torque
Immunity
Emission
Specifications are subject to change without notice (06.11.01)
a
screwdriver
Measuring range
OFF ON OFF OFF
ON OFF OFF OFF
OFF OFF OFF OFF 5 to 50 VAC/DC
ON OFF ON OFF
ON OFF OFF ON
as
Centre knob:
Setting of voltage on relative
scale: from 10 to 110% of the
full-scale value.
Hysteresis:
Approx. 4% of set value, it
can be extended by inserting
a resistor between terminals
Z1, Y1 or 8, 9.
Approx. resistor values:
10%:
25%:
50%:
75%:
Latch:
< 100 ms
(voltage rising from
-20% to +20% set value)
< 300 ms
(voltage decreasing from
+20% to -20% set value)
(15 min warm-up time)
± 1000 ppm/°C
± 0.5% on full-scale
LED, green
LED, red
(EN 60529)
IP 20
3 (DUA01), 2 (PUA01)
-20 to 60°C, R.H. < 95%
-30 to 80°C, R.H. < 95%
22.5 x 80 x 99.5 mm
36 x 80 x 87 mm
Approx. 150 g
Max. 0.5 Nm
acc. to IEC 60947
UL, CSA (except 748)
Yes
Electromagnetic Compatibillity
According to EN 61000-6-2
According to EN 50081-1
20 to 200 VAC/DC
50 to 500 VAC/DC
0.4 to 4 V
2 to 20 VAC/DC
< 500
180 k
47 k
22 k
15 k
p