60.12.8.024.0040 FINDER, 60.12.8.024.0040 Datasheet

POWER RELAY, DPDT, 24VAC, 10A, PLUG IN

60.12.8.024.0040

Manufacturer Part Number
60.12.8.024.0040
Description
POWER RELAY, DPDT, 24VAC, 10A, PLUG IN
Manufacturer
FINDER
Datasheet

Specifications of 60.12.8.024.0040

Relay Type
General Purpose
Coil Voltage Vac Nom
24V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Coil Resistance
74ohm
Contact Configuration
DPDT
Coil Type
AC
Coil Current
90mA
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Plug-in mount
10 A General purpose relay
Features
Contact specification
Contact configuration
Rated current/Maximum peak current
Rated voltage/Maximum switching voltage V AC
Rated load AC1
Rated load AC15 (230 V AC)
Single phase motor rating (230 V AC)
Breaking capacity DC1: 30/110/220 V
Minimum switching load
Standard contact material
Coil specification
Nominal voltage (U
Rated power AC/DC
Operating range
Holding voltage
Must drop-out voltage
Technical data
Mechanical life AC/DC
Electrical life at rated load AC1
Operate/release time
Insulation between coil and contacts (1.2/50 µs) kV
Dielectric strength between open contacts
Ambient temperature range
Environmental protection
Approvals (according to type)
2 & 3 pole changeover contacts
(preferred version)
UL Listed (certain relay/socket
combinations)
Contact material options
Lockable test button with mechanical flag
indicator (preferred version)
90 series sockets, coil EMC suppression
and timer accessories
Cadmium Free contacts
AC coils & DC coils
N
)
V AC (50/60 Hz)
VA (50 Hz)/W
mW (V/mA)
AC/DC
AC/DC
cycles
cycles
V DC
V AC
kW
AC
DC
VA
VA
ms
°C
A
A
2 pole - 10 A power contacts
8 pin plug-in
32.5
20 · 10
12
14
11
0.8 U
0.2 U
60 Series - General purpose relays 6 - 10 A
10/0.4/0.15
(0.8…1.1)U
(0.8…1.1)U
A1
2 CO (DPDT)
4
3
1
500 (10/5)
–40…+70
250/400
200 · 10
2
2.2/1.3
60.12
10/20
2,500
1,000
AgNi
0.37
500
N
N
9/9
RT I
6
3.6
/0.5 U
/0.1 U
/50 · 10
6 - 12 - 24 - 48 - 60 - 110 - 120 - 230 - 240 - 400
36.4
A2
22
24
21
3
7
6 - 12 - 24 - 48 - 60 - 110 -125 - 220
N
N
5
6
8
N
N
6
3 pole - 10 A power contacts
11 pin plug-in
20 · 10
32.5
0.8 U
0.2 U
10/0.4/0.15
(0.8…1.1)U
(0.8…1.1)U
3 CO (3PDT)
12
14
11
500 (10/5)
–40…+70
22
200 · 10
250/400
A1
4
3
1
2.2/1.3
60.13
5
10/20
2,500
1,000
2
AgNi
0.37
500
N
N
9/9
21
3.6
RT I
6
/0.5 U
/0.1 U
/50 · 10
6
36.4
A2
24
3
31
32
34
N
N
10
7
11
N
N
8
9
6
83
60

Related parts for 60.12.8.024.0040

60.12.8.024.0040 Summary of contents

Page 1

... AgNi 110 - 120 - 230 - 240 - 400 110 -125 - 220 2.2/1.3 (0.8…1.1 (0.8…1.1)U N 0 0 · /50 · 200 · 9/9 3.6 1,000 °C –40…+ 60.13 3 pole - 10 A power contacts • 11 pin plug-in • 32.5 36 (3PDT) 10/20 250/400 ...

Page 2

... Breaking capacity DC1: 30/110/220 V Minimum switching load mW (V/mA) Standard contact material Coil specification Nominal voltage ( (50/60 Hz) N Rated power AC/DC VA (50 Hz)/W Operating range Holding voltage Must drop-out voltage Technical data Mechanical life AC/DC Electrical life at rated load AC1 Operate/release time Insulation between coil and contacts (1.2/50 µ ...

Page 3

... N DC (0.8…1.1)U N 0 0 · /50 · 200 · 9/9 3.6 1,000 °C –40…+ 60.63 3 pole - 10 A power contacts • Flange mount/Faston 187 • 32.2 36.5 3.6 7 5.9 6.2 4 (3PDT) 10/20 250/400 2,500 500 0.37 10/0 ...

Page 4

... A2 Lockable test button and mechanical flag indicator (0040) The dual-purpose Finder test button can be used in two ways: Case 1) The plastic pip (located directly above the test button) remains intact. In this case, when the test button is pushed, the contacts operate. When the test button is released the contacts return to their former state ...

Page 5

... Conducted disturbance immunity Burst (5...50)ns, 5 kHz Surge (1.2/50 µ (differential mode) Other data Bounce time: NO/NC Vibration resistance (5…55)Hz, max. ± 1 mm: NO/NC Shock resistance Power lost to the environment Contact specification Electrical life (AC) v contact current 7 10 Resistive load - cosϕ Inductive load - cosϕ ...

Page 6

... Current sensing AC coil data to be energised, Coil code 4251 4181 4161 4121 4101 4051 4041 4031 4021 4011 Other types of current sensing relays are available on request - (A) (A) ( min N max 1.7 2.0 2.4 1.5 1 ...

Page 7

... Example series P.C.B.relay (3PDT) with coil rated No. of poles Series (DPDT (3PDT) Type 4 = P.C. Coil version = Series General Purpose Relays 10 A ORDERING INFORMATION Coil version diode in parallel to coil (positive to pin (50/60 Hz Coil voltage 006 = 6 V 012 = 12 V 024 = 24 V 048 = 48 V 060 = 60 V 110 = 110 V ...

Page 8

... Series General Purpose Relays 10 A DIELECTRIC STRENGTH tested at leakage current ≤ for 1 min SURGE TEST (1.2/50 µs) BETWEEN COIL AND CONTACTS ISOLATION RESISTANCE ISOLATION GROUP MAXIMUM SWITCHING FREQUENCY 60.43 AMBIENT TEMPERATURE MECHANICAL LIFE RINA C PROTECTION CATEGORY OF ENCLOSURES OPERATE AND RELEASE TIME ...

Page 9

... Contact life vs AC1 load at 1800 cycles/ 0.8 k 0.6 0.4 1 0.8 0.6 0.4 COS Load reduction factor vs cos 60 Series General Purpose Relays 10 A 2.5 3 Breaking capacity for DC1 load at 1800 cycles/ load applied to 1 contact B = load applied to 2 contacts in series C = load applied to 3 contacts in series 0 ...

Page 10

... VERSIONS alternating current 50/ direct current AM - current sensing coil with a diode in parallel RATED POWER OPERATING RANGE HOLDING VOLTAGE MUST DROP-OUT VOLTAGE NOMINAL MAGNETOMOTIVE FORCE THERMAL INSULATION CLASS OF WIRE THERMAL RESISTANCE CONDUCTED DISTURBANCE IMMUNITY AC VERSION DATA R values relate to +20°C. Tolerance of R and I values: ± 10%. ...

Page 11

... DC coil min pick-up voltage vs ambient temperature. Umin = pick-up voltage U = rated voltage HEATING TIME (min) Temperature rise "∆t " vs applied voltage coils. 60 Series General Purpose Relays 10 A COIL SPECIFICATIONS Temperature rise "∆t " vs applied voltage. DC coils Temperature rise "∆t " vs applied voltage coils. ...