G2R-1A-E-DC18 Omron, G2R-1A-E-DC18 Datasheet - Page 6

POWER RELAY SPST-NO 18VDC, 16A, PC BOARD

G2R-1A-E-DC18

Manufacturer Part Number
G2R-1A-E-DC18
Description
POWER RELAY SPST-NO 18VDC, 16A, PC BOARD
Manufacturer
Omron
Datasheet

Specifications of G2R-1A-E-DC18

Relay Type
High Capacity
Coil Voltage Vdc Nom
18V
Contact Current Max
16A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Contact Configuration
SPST-NO
Coil Type
DC
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
G2R
Double-winding Latching Relays
Note:
I
UL 508 (File No. E41643)
6
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
G2R-1
G2R-14
G2R-1-H
G2R-1-S
G2R-1-T
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E
G2R-1A-E
G2R-2
G2R-24
G2R-2-H
G2R-2-S
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI
Approved Standards
Values in the above table are the initial values.
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Model
Item
SPDT
SPST-NO
SPDT
SPST-NO
DPDT
DPST-NO
SPST-NO
30 m
20 ms max.
20 ms max.
30 ms max.
Mechanical:18,000 operations/hr
Electrical:
1,000 M
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: Set: 500 m/s
Reset:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Operating: 40°C to 70°C (with no icing)
Operating: 5% to 85%
Approx. 17 g
Contact form
max.
min. (at 500 VDC)
1,800 operations/hr (under rated load)
100,000 operations min. (at 1,800 operations/hr under rated load)
100 m/s
2
1 pole
(approx. 10G)
2
3 to 110 VDC
3 to 240 VAC
(approx. 100G)
2
Coil ratings
(approx. 50G); 200m/s
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
16 A, 30 VDC (resistive, NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); 1/3 hp, 120 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only)
10 A, 30 VDC (resistive)
2
50 m
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between contacts
of different poles
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
(approx. 20G)
max.
Contact ratings
2 poles
G2R

Related parts for G2R-1A-E-DC18