G2R-1-T 110VAC Omron, G2R-1-T 110VAC Datasheet - Page 7

RELAY, FLANGE, 110VAC

G2R-1-T 110VAC

Manufacturer Part Number
G2R-1-T 110VAC
Description
RELAY, FLANGE, 110VAC
Manufacturer
Omron
Datasheet

Specifications of G2R-1-T 110VAC

Relay Type
Power
Coil Voltage Vac Nom
110V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
5.5kohm
Coil Type
AC Coil, Monostable
Coil Current
11mA
Nom
RoHS Compliant
Contact Configuration
SPCO
Rohs Compliant
Yes
G2R
Double-winding Latching Relays
Note: Values in the above table are the initial values.
UL 508 (File No. E41643)
Contact resistance
Set time
Reset time
Min. set/reset signal width
Max. operating frequency
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Life expectancy
Weight
G2R-1
G2R-14
G2R-1-H
G2R-1-S
G2R-1-T
G2R-1A
G2R-1A4
G2R-1A-H
G2R-1A-S
G2R-1A-T
G2R-1-E
G2R-1A-E
G2R-2
G2R-24
G2R-2-H
G2R-2-S
G2R-2A
G2R-2A4
G2R-2A-H
G2R-2A-S
G2R-1A-ASI
Approved Standards
*2,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A socket is mounted.
Model
Item
SPDT
SPST-NO
SPDT
SPST-NO
DPDT
DPST-NO
SPST-NO
30 m max.
20 ms max.
20 ms max.
30 ms max.
Mechanical: 18,000 operations/hr
Electrical:
1,000 M min. (at 500 VDC)
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
1,000 VAC, 50/60 Hz for 1 min between contacts
of same pole;
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
Destruction: 10 to 55 Hz, 1.5 mm double amplitude
Malfunction: 10 to 55 Hz, 1.5 mm double amplitude
Destruction: 1,000 m/s
Malfunction: Set:
Mechanical: 10,000,000 operations min (at 18,000 operations/hr)
Electrical:
Approx. 17 g
Contact form
Reset: 100 m/s
100,000 operations min. (at 1,800 operations/hr under rated load)
1,800 operations/hr (under rated load)
500 m/s
1 pole
3 to 110 VDC
3 to 240 VAC
2
(approx. 100G)
Coil ratings
2
2
(approx. 10G)
(approx. 50G); 200m/s
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-3 (NO contact only)
16 A, 30 VDC (resistive, NO contact only)
16 A 250 VAC (general use NO contact only)
16 A, 250 VAC (general use, NO contact only)
TV-3 (NO contact only); 1/3 hp, 120 VAC
5 A, 30 VDC (resistive)
5 A, 250 VAC (general use)
TV-3 (NO contact only)
10 A, 30 VDC (resistive)
10 A, 250 VAC (general use)
TV-5/TV-8 (NO contact only)
50 m max.
5,000 VAC, 50/60 Hz for 1 min between coil and
contacts*;
3,000 VAC, 50/60 Hz for 1 min between
contacts of different poles
1,000 VAC, 50/60 Hz for 1 min between
contacts of same pole
1,000 VAC, 50/60 Hz for 1 min between set and
reset coil
2
(approx. 20G)
Contact ratings
2 poles
G2R
7