G5SB-14 24DC Omron, G5SB-14 24DC Datasheet - Page 2

RELAY, PCB, 24VDC

G5SB-14 24DC

Manufacturer Part Number
G5SB-14 24DC
Description
RELAY, PCB, 24VDC
Manufacturer
Omron
Datasheet

Specifications of G5SB-14 24DC

Relay Type
Power
Coil Voltage Vdc Nom
24V
Contact Current Max
5A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
1.44kohm
Coil Type
DC Coil
Coil Current
16.7mA
Nom Operating
RoHS Compliant
Contact Configuration
SPDT
Rohs Compliant
Yes
■ Contact Ratings
Note: P level: λ 60=0.1 x 10
■ Characteristics
Note: 1. The data shown above are initial values.
■ Approved Standards
UL508 (File No. E41515)
CSA C22.2 (No. 14) (File No. LR31928)
Electrical durability tests are performed at 70 ° C.
2
Load
Rated load
Contact material
Rated carry current
Max. switching voltage
Max. switching current
Max. switching capacity
Min. permissible load
Contact resistance (See note 2.)
Operate time (See note 3.)
Release time (See note 3.)
Insulation resistance (See note 4.)
Dielectric strength
Impulse withstand voltage
Vibration resistance
Shock resistance
Durability (See note 5.)
Ambient temperature
Ambient humidity
Weight
G5SB
2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method.
3. The operating time is possible with the operating voltage imposed with no contact bounce at an ambient temperature of 23 ° C.
4. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC.
5. The electrical durability data items shown are possible at 23 ° C.
Model
PCB Relay
–6
G5SB
5 to 24 VDC
operation (with an operating frequency of 120 operations/min.)
Coil ratings
Resistive load
3 A (NO)/3 A (NC) at 125 VAC
5 A (NO)/3 A (NC) at 125 VAC
5 A (NO) at 250 VAC
3 A (NC) at 250 VAC
5 A (NO)/3 A (NC) at 30 VDC
Ag alloy
5 A (NO)/3 A (NC)
250 VAC, 30 VDC
5 A (NO)/3 A (NC)
1,250 VA, 150 W (NO)
750 VA, 30 W (NC)
10 mA at 5 VDC
100 m Ω max.
10 ms max.
5 ms max.
1,000 M Ω min.
4,000 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
8 kV (1.2 x 50 µ s)
Destruction: 10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Malfunction: 10 to 55 Hz, 0.75-mm single amplitude (1.5-mm double amplitude)
Destruction:
Malfunction:
Non-energized: 100 m/s
Mechanical: 5,000,000 operations (18,000 operations per hour)
Electrical:
Switching frequency: 1,800 operations per hour
Operating: –40 ° C to 70 ° C with no icing or condensation
Operating:
Approx. 6.5 g
200,000 operations:
50,000 operations:
50,000 operations:
10,000 operations:
10,000 operations:
5% to 95%
1,000 m/s
Energized: 100 m/s
3 A, 125 VAC (resistive) NC only
2 A, 125 VAC (resistive) NC only
5 A, 250 VAC (resistive) NO only
3 A, 250 VAC (resistive) NO only
5 A, 30 VDC (resistive) NO only
2
(approximately 10G)
2
(approx. 100G)
Contact ratings
3 A (NO)/3 A (NC) at 125 VAC resistive load
5 A (NO)/3 A (NC) at 125 VAC resistive load
5 A (NO) at 250 VAC resistive load
3 A (NC) at 250 VAC resistive load
5 A (NO)/3 A (NC) at 30 VDC resistive load
2
(approximately 10G)
6,000
Number of test operations