MKS2PIAC110 Omron, MKS2PIAC110 Datasheet

no-image

MKS2PIAC110

Manufacturer Part Number
MKS2PIAC110
Description
RELAY, DPCO, 110VAC
Manufacturer
Omron
Datasheet

Specifications of MKS2PIAC110

Relay Type
General Purpose
Coil Voltage Vac Nom
110V
Contact Current Max
10A
Contact Voltage Ac Nom
250V
Contact Voltage Dc Nom
30V
Coil Resistance
1240ohm
Coil Type
AC Coil
Coil Current
24.2mA
Nom
RoHS Compliant
Contact Configuration
DPDT
Rohs Compliant
Yes
General-purpose Relays Featuring
Mechanical Indicator and Lockable Test
Button
• Built-in operation indicator (mechanical and LED), and new
• Nameplate provided on models with lockable test button.
• RoHS Compliant.
• UL approval for most models. (UL approval pending for models
Features
Two-way Action Test Button
Model Number Structure
■ Model Number Legend
1. Contact Form
2. Terminals
3. Mechanical Indicator/Test Button
4. LED Indicator
MKS@@@@@-@-@
models with lockable test button.
with built-in LED indicators.)
General-purpose Relays
MK-S New Model
2: DPDT
3: 3PDT
P: Plug-in
Blank: Mechanical indicator
I:
Blank: Standard
N:
1 2 3 4 5
Mechanical indicator and lockable test button
LED indicator
6
7
Normal Operation
Relay in
Yellow
button
Pull down the test
button to the first
position, then press the
yellow button with an
insulated tool to
operate the contact.
For Momentary
Operation
General-purpose Relays
5. Coil Polarity
6. Surge Absorption
7. Internal Connections
8. Rated Voltage
Blank: Standard
1:
Blank: Standard
D:
V:
Blank: Standard
2 or 5: Non-standard connections (Refer to “Terminal
(Refer to “Coil Ratings”.)
Pull down the test
button to the second
position.
(The contact is now in
the locked position.)
Reverse polarity (DC coil only)
Surge absorber diode (DC coil only)
Surge absorber varistor (AC coil only)
Arrangement/Internal Connection”.)
Operation
For Lock
MK-S New Model
1

Related parts for MKS2PIAC110

MKS2PIAC110 Summary of contents

Page 1

... General-purpose Relays MK-S New Model General-purpose Relays Featuring Mechanical Indicator and Lockable Test Button • Built-in operation indicator (mechanical and LED), and new models with lockable test button. • Nameplate provided on models with lockable test button. • RoHS Compliant. • UL approval for most models. (UL approval pending for models with built-in LED indicators ...

Page 2

... Refer to Terminal Arrangement and Internal Connections for non-standard internal connections. ■ List of Models (Order Separately) Item Type Track-mounted Socket 8-pin 11-pin 8-pin 11-pin Hold-down Clip (For PF083A-E and PF113A-E) 2 General-purpose Relays Internal connections With mechanical indicator With mechanical indicator (See note 3.) Standard MKS2P Non-standard MKS2P-2 Standard MKS3P Non-Standard ...

Page 3

... For DC-operated Relays with the LED indicator built-in, add an LED current of approx the rated current. Contact Ratings Load Contact mechanism Contact material Rated load NO NC Rated carry current Max. switching voltage Max. switching current Max. switching power NO NC Coil resistance Must operate voltage 3.1 Ω 80% max. of rated 30% min. of rated voltage voltage 13.7 Ω ...

Page 4

... A, 250 V AC 50/60 Hz (General Use) CSA Standard: CSA Certification by : CSA C22.2 No. 14 Note: Applications have been submitted for UL and CSA certification for models with built-in LED indicators. Engineering Data ■ Reference Data Maximum Switching Power 100 resistive load with NO contact AC resistive load ...

Page 5

... A PF083A-D PF083A PF113A-E-D PF113A PF113A-E (Conforming to EN 50022) Terminal Arrangement Eleven, M3.5 × 7 sems 52 max. Mounting Holes 4 Two two 4.5-dia. holes 33±0.2 General-purpose Relays 34.5 max. 0.8 52.5 max. Terminal Arrangement 7 4 35.4 Mounting Holes 3 42.8 max. Two two 4.5-dia. holes 31 max ...

Page 6

... This dimension applies to the PFP-50N Mounting Track. Mounting Height with Sockets Surface-mounting Sockets Two 87.8 77.8 poles (See (See note.) note.) 74.3 PF083A(-E) Note: PF083A(-E) and PF113A(-E) allow either track or screw mounting. 6 General-purpose Relays PF113A-D Terminal Arrangement Eight, M4 screws 1 2 ...

Page 7

... Models with Diode MKS2P(I)1-D (DC Coil: Reverse Polarity Models with MKS2P(I)N-D LED indicator 4 (DC Coil MKS2P(I)-2 MKS3P( MKS2P(I)N-2 MKS3P(I MKS2P(I)N-2 MKS3P(I MKS2P(I)N1-2 MKS3P(I) MKS2P(I)-D-2 MKS3P(I)- MKS2P(I)1-D-2 MKS3P(I)1 MKS2P(I)N-D-2 MKS3P(I)N General-purpose Relays (Bottom View) MKS3P(I)- MKS3P(I)N MKS3P(I)N MKS3P(I)N1-2 MKS3P(I)N1 MKS3P(I)-D MKS3P(I)1-D-2 MKS3P(I)1-D MKS3P(I)N-D-2 MKS3P(I)N-D ...

Page 8

... Models with test buttons or LED indicators fulfill the requirements for reinforced insulation between live parts and the front of cover only when the Relay complete condition, i.e. with the nameplate, nameplate frame, test button, and slider in place. If any of these parts are removed, only the requirements for basic insulation are fulfilled. 8 General-purpose Relays MKS2P(I)-V-2 MKS3P(I)-V 5 ...

Page 9

... MK-S New Model General-purpose Relays 9 ...

Page 10

... General-purpose Relays MK-S New Model ...

Page 11

... MK-S New Model General-purpose Relays 11 ...

Page 12

... COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR ...