V23074A1001A403 Tyco Electronics, V23074A1001A403 Datasheet - Page 3

SIGNAL RELAY SPDT-CO 12VDC, 25A, PLUG IN

V23074A1001A403

Manufacturer Part Number
V23074A1001A403
Description
SIGNAL RELAY SPDT-CO 12VDC, 25A, PLUG IN
Manufacturer
Tyco Electronics
Datasheet

Specifications of V23074A1001A403

Contact Configuration
SPCO
Contact Current Max
25A
Contact Voltage Dc Nom
12V
Coil Voltage Vdc Nom
12V
Coil Resistance
105ohm
Coil Power Cont
1.4W
Coil Type
DC, Monostable
Contact Form
1 Form C
Coil Voltage
12 V
Contact Rating
15 A, 25 A
Mounting Style
PCB
Power Consumption
1.4 W
Contact Material
Silver Tin Oxide
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
63
Contact data
Contact configuration
Circuit symbol
Rated voltage
Rated current at 85 °C
Contact material
Max. switching voltage/power
Max. switching current
On
Off
Min. recommended load
Voltage drop at 10 A (initial)
Mechanical endurance (without load)
Electrical endurance
(example of resistive load,
further information on request)
Max. switching rate at nominal load
1)
2)
3)
Load limit curve
See chapter Diagnostics in our Application Recommendations on page 18 of this catalog or consult the internet at http://relays.tycoelectronics.com/application.asp
The values apply to a resistive or inductive load with suitable spark suppression and at maximum 13.5 V for 12 V or 27 V for 24 V load voltages.
For a load current duration of maximum 3 s for a make/break ratio of 1:10.
2)
Pin assignment
1 make contact/
1 form A
Value of resistor see ordering information
Other components in parallel to the coil
available on request
1)
3)
S_R_WMF
NO contact
NC contact
Plug-In Relays
Micro ISO Relays
Micro Relay A / VFM A
> 1 x 10
1 changeover contact/
1 form C
25 A, 14 V
120 A
12 V
25 A
30 A
5
operations
Typ. 15 mV, 200 mV max.
Make contact/
Form A
W_R_WMF
Please observe the disclaimer.
> 1 x 10
15 A, 28 V
120 A
24 V
15 A
20 A
5
operations
6 operations per minute (0.1 Hz)
See load limit curve
Typ. 10
Load limit curve 1
during transit time (changeover contact)
Load limit curve 2
no stationary arc (make contact)
1 A at 5 V
AgSnO
7
operations
2
> 1 x 10
> 1 x 10
(NO contact)
(NC contact)
25 A, 14 V
15 A, 14 V
40/120 A
15/25 A
15/30 A
^
= arc extinguishes,
^
= safe shutdown,
NC/NO
12 V
5
5
operations
operations
Typ. 15 mV, 200 mV max.
Typ. 20 mV, 250 mV max.
Changeover contact/
Form C
> 1 x 10
> 1 x 10
Catalog 1308028
(NO contact)
(NC contact)
15 A, 28 V
10 A, 28 V
20/120 A
10/15 A
10/20 A
NC/NO
24 V
5
5
Revision 03-06
Revision 03-05
operations
operations

Related parts for V23074A1001A403