AGN20012 PANASONIC EW, AGN20012 Datasheet
AGN20012
Specifications of AGN20012
Available stocks
Related parts for AGN20012
AGN20012 Summary of contents
Page 1
... Due to highly efficient magnetic circuit design, leakage flux is reduced and changes in electrical characteristics from components being mounted All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. GN RELAYS (AGN) close-together are minimized. This all means a packaging density higher than ever before. inch, 6 ...
Page 2
... DC 12V DC 24V DC *Pulse drive (JIS C 5442-1996) All Rights Reserved © COPYRIGHT Panasonic Electric Works Co., Ltd. Single side stable Part No. AGN2001H AGN20003 AGN2004H AGN20006 AGN20009 AGN20012 AGN20024 Single side stable Part No. AGN200 1H AGN200 03 AGN200 4H AGN200 06 AGN200 09 AGN200 12 AGN200 24 Single side stable Part No ...
Page 3
GN (AGN) 3) High sensitivity single side stable type Nominal coil Set voltage voltage ( 1. 4.5V DC 80%V or less of 10%V or more nominal voltage* nominal voltage* 9V ...
Page 4
... 100 110 120 130 140 150 4 Coil applied voltage Ambient temperature characteristics Tested sample: AGN2004H, 6 pcs. Drop-out voltage -40 -20 0 Pick-up voltage 120 9-(2). Influence of adjacent mounting Tested sample: AGN20012, 6 pcs Pick-up voltage -10 10 OFF OFF 5 Drop-out voltage 0 OFF -5 - .079 .157 .236 .315 .394 .472 ...
Page 5
... Please chuck the 80 dia. 3.150 dia. Avoid chucking the center of the relay. In addition, excessive chucking pressure to the pinpoint of the relay should be avoided. For general cautions for use, please refer to the “Cautions for use of Signal Relays” or “General Application Guidelines”. B portion. ...