G6EK-134P-US 5DC Omron, G6EK-134P-US 5DC Datasheet - Page 3

RELAY, PCB, SPCO, 5VDC, LATCHING

G6EK-134P-US 5DC

Manufacturer Part Number
G6EK-134P-US 5DC
Description
RELAY, PCB, SPCO, 5VDC, LATCHING
Manufacturer
Omron
Datasheet

Specifications of G6EK-134P-US 5DC

Contact Current Max
3A
Contact Voltage Ac Nom
125V
Contact Voltage Dc Nom
30V
Coil Voltage Vdc Nom
5V
Coil Resistance
125ohm
Coil Power
RoHS Compliant
Coil Type
DC Coil, Sensitive
Coil Current
40mA
Contact Configuration
SPDT
Rohs Compliant
Yes
G6E
Note:
Note:
UL508 (File No. E41515)/CSA C22.2, No.14 (File No. LR31928)
Contact resistance (See note 1.)
Operate (set) time (See note 2.)
Release (reset) time (See note 2.)
Min. set/reset signal width
Max. operating frequency
Insulation resistance (See note 3.)
Dielectric withstand voltage
Impulse withstand voltage
Vibration resistance
Shock resistance
Endurance
Ambient temperature
Ambient humidity
Weight
SPDT
Characteristics
Approved Standards
The values here are initial values.
1. The contact resistance was measured with 1 A at 5 VDC using a voltage-drop method.
2. Values in parentheses are actual values.
3. The insulation resistance was measured with a 500-VDC megohmmeter applied to the same parts as those used for checking
Contact form
the dielectric strength.
3 to 48 VDC
Coil ratings
50 m Ω max.
5 ms max. (approx. 2.9 ms; 48 VDC type: approx. 2.4 ms)
5 ms max. (approx. 1.3 ms)
Latching type: 15 ms min. (at 23°C)
Mechanical: 36,000 operations/hr
Electrical: 1,800 operations/hr (under rated load)
1,000 M Ω min. (at 500 VDC)
1,500 VAC, 50/60 Hz for 1 min between coil and contacts
1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity
1,500 V (10 x 160 µs) (conforms to FCC Part 68)
Destruction: 10 to 55 to 10 Hz, 2.5-mm single amplitude (5-mm double amplitude)
Malfunction: 10 to 55 to 10 Hz, 1.65-mm single amplitude (3.3-mm double amplitude)
Destruction: 1,000 m/s
Malfunction: 300 m/s
Mechanical: 100,000,000 operations min. (at 36,000 operations/hr)
Electrical: 100,000 operations min. (0.4 A at 125 VAC resistive load;
0.2 A at 125 VAC inductive load)
500,000 operations min. (2 A at 30 VDC resistive load;
1 A at 30 VDC inductive load)
200,000 operations min. (3 A at 30 VDC resistive load)
Operating: − 40°C to 70°C (with no icing)
5% to 85%
Approx. 2.7 g
2
0.2 A, 250 VAC (general use)
0.6 A, 125 VAC (general use)
2 A, 30 VDC (resistive)
0.6 A, 125 VDC (resistive, Ag contact only)
2
Contact ratings
G6E
59

Related parts for G6EK-134P-US 5DC