V23079C1101B301 Tyco Electronics, V23079C1101B301 Datasheet
V23079C1101B301
Specifications of V23079C1101B301
Related parts for V23079C1101B301
V23079C1101B301 Summary of contents
Page 1
The Best Relaytion P2 Relay 108-98002 Rev. C EC-JM00-0009-03 ECOC: JM10 1. Apr. 04 ...
Page 2
... European Directive conformance: P2 relay product conformance according to Compliance is evidenced by written declaration from all raw material suppliers. Tyco Electronics AXICOM only has responsibility for the proper processing of these materials. Confirmation is valid for date codes ≥ 0427 Page 2 (14) 108-98002 Rev. C ³ 300 Vrms ³ ...
Page 3
P2 Relay Dimensions THT THT V23079-x1xxx-B301 V23079-x2xxx-B301 standard coil overmolded coil mm inch mm L 14.5 ± 0.1 0.570 ± 0.004 14.6 ± 0.1 0.575 ± 0.00414.5 ± 0.1 W 7.2 ± 0.1 0.283 ± 0.004 7.2 ± 0.1 0.283 ...
Page 4
P2 Relay Coil Data (values at 23°C) Nominal Operate/set voltage range voltage Unom Minimum Maximum voltage U voltage U min max Vdc Vdc Vdc THT, non-latching, standard coil 3 2.25 6.50 4 3.00 8.70 4.5 3.38 9.80 5 3.75 10.90 ...
Page 5
P2 Relay Coil Data (values at 23°C) Nominal Operate/set voltage range voltage Unom Minimum Maximum voltage U voltage U min max Vdc Vdc Vdc SMT, long pins, latching, 2 standard coils 2.4 1.80 5.20 3 2.25 6.50 4.5 3.38 9.80 ...
Page 6
P2 Relay Ordering Code Identification of the Miniature Relay P2 Relay type THT version SMT version with long terminals A = non-latching, 1 coil D = non-latching, 1 coil B = latching, 2 coils E = latching, 2 coils C ...
Page 7
... Upper limit of the operative range of the coil voltage (limiting voltage) when coils are continously energized = Lower limit of the operative range of the coil voltage (reliable operate voltage) For latching relays U resp. U set min. reset = Lower limit of the operative range of the coil voltage (reliable release voltage) ...
Page 8
P2 Relay Contact Data Number of contacts and type Contact assembly Contact material Limiting continuous current at max. ambient temperature Maximum switching current Maximum swichting voltage Maximum switching capacity Thermoelectric potential Minimum switching voltage Initial contact resistance / measuring condition: ...
Page 9
P2 Relay Insulation Insulation resistance at 500 VDC Dielectric test voltage (1 min) between coil and contacts (Relay with 1 coil) between adjacent contact sets between open contacts Surge voltage resistance according to Bellcore TR-NWT-001089 ( ms) between ...
Page 10
P2 Relay Recommended soldering conditions Soldering conditions according CECC 00802 sec 215° C 180° C 130° C external preheating 100° C Time (s) Vapor Phase Soldering: Temperature/Time Profile (Lead Temperature) Full line: typical Dotted line: process limits ...
Page 11
... Tape and reel for SMT version with long terminals - 400 relays per reel, 2000 relays per box 4 ±0,1 1,5 ±0,1 2 ±0 2,2 16 ±0,1 Tape and reel for SMT version with short terminals - 500 relays per reel, 2500 relays per box 4 ±0,1 1,5 ±0,1 2 ±0 1,5 ±0,1 12 ±0,1 ...
Page 12
P2 Relay Option: high dielectric between open contacts (overmolded coil) This supplementary data sheet refers to the basic data sheet of the P2 relay series (V23079) with following additions: - Dielectric strength 1500 V rms adjacent contact sets - Only ...
Page 13
... Nominal voltage range from 5 ... 24 V, coil power consumption 50...280 mW for 1 n/o and 125 ... 280 mW for 2 n c/o versions. Reedrelays are available in DIP or SIL housing and capable to switch currents up to 0,5 A. Integrated diode and/or electrostatic shield optional. Dielectric strength 1500 Vdc ...
Page 14
... E-mail: axicom@tycoelectronics.com Tyco Electronics Paulsternstrasse 26 D-13629 Berlin / Germany Phone +49 30 386 38573 Fax +49 30 386 38575 E-mail: axicom@tycoelectronics.com Tyco Electronics EC Trutnov s.r.o. Komenského 821 CZ-541 01 Trutnov / Czech Republic E-mail: axicom@tycoelectronics.com Tyco Electronics Corporation POB 3608, Harrisburg, PA 17105, USA Phone +001 800-522-6752 Page 14 (14) 108-98002 Rev ...