4210-115-60FPM ARTISAN CONTROLS, 4210-115-60FPM Datasheet

SOLID STATE FLASHER, 60FPM, 115VAC

4210-115-60FPM

Manufacturer Part Number
4210-115-60FPM
Description
SOLID STATE FLASHER, 60FPM, 115VAC
Manufacturer
ARTISAN CONTROLS
Datasheets

Specifications of 4210-115-60FPM

Nom Input Voltage
115VAC
Delay Time Range
60FPM
Timing Adjustment
Fixed
Relay Mounting
Panel
Contact Rating
1A, 115VAC
Time Range
1 To 60FPM
Flash Rate Per Minute
60
Supply Voltage
115VAC
Current, Rating
10 mA-1 A
Depth
0.36 in.
Duty Cycle
50%
Function
Timing
Length
2.65 in.
Relay Type
Solid State
Standards
UL
Temperature, Operating, Maximum
85 °C
Temperature, Operating, Minimum
-20 °C
Termination
Quick Connect
Timer Type
Flasher
Timing Range
60 FPM
Voltage, Control
115 VAC
Width
2.25 in.
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
AC Circuit
Notice: Artisan Controls Corporation assumes no responsibility for customers applications or product design. The information and data contained herein is
the sole and exclusive property of Artisan Controls Corporation. Any duplication, misuse, or conversion of this information without the express written
consent of Artisan Controls Corporation is illegal and will result in damages including court costs and attorney fees being assessed against the party
misusing this property
Mechanical & Wiring . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Timing Diagram . . . . . . . . . . . . . . .
Operating Voltage
Output
OFF
OFF
Alternate Wiring
Output Always Turns ON First With
Tel: 973-598-9400 • Fax: 973-598-9410 • Toll Free: 800-457-4950
Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA
Application of Operating Voltage
ON
V
ON
I S I T
Solid State Timers and Controllers
ON Time = OFF Time
O U R
4210
The Model 4210 is an all solid state flasher intended for use in AC circuits only.
Capable of flashing a load circuit up to one ampere at a fifty percent duty cycle.
Output switch is ON for as long as it is OFF. Flash rates from 1 flash per minute
up to 300 flashes per minute are available in five operating voltage ranges. The
model 4210 has internal transient protection devices to assure reliable
operation even when driving inductive load circuits such as relays or solenoids.
W E B
.250 Quick
Terminals
Connect
S I T E
Mtg. Holes
.156 Dia.
4 Places
How To Find The Flash Rate . . . . . . . . . . . . . . .
Timing Period vs Timing Resistance Range
The timing diagram shown below is for an application that
requires the load circuit to be ON for 750 milliseconds and OFF
for 750 milliseconds. (Remember - the ON and OFF times will
essentially be equal due to the 50% duty cycle specification
inherent in the model 4210)
The voltage across the load circuit would look something this:
A T
50%
ON
:
www.artisancontrols.com
50%
OFF
1.70
ON Time = 0.75 Sec (750 milliseconds)
OFF Time = 0.75 Sec (750 milliseconds)
Flash Period = ON + OFF Time
Flash Period = .750 + .750 = 1.5 Seconds
Flash Rate in Flashes Per Minute (FPM)
FPM = 60 / Flash Period
FPM = 60 / 1.5 = 40 Flashes Per Minute
.27
.90
2.25
AC Flasher
Solid State
.36
.76
.20
2.65

Related parts for 4210-115-60FPM

4210-115-60FPM Summary of contents

Page 1

... Artisan Controls Corporation, 111 Canfield Ave., Bldg B15-18, Randolph, NJ, 07869, USA 4210 The Model 4210 is an all solid state flasher intended for use in AC circuits only. Capable of flashing a load circuit up to one ampere at a fifty percent duty cycle. Output switch is ON for as long OFF. Flash rates from 1 flash per minute up to 300 flashes per minute are available in five operating voltage ranges ...

Page 2

... A model 4210 operating from 24V AC with a flash rate of 90 flashes-per-minute (FPM) The load circuit will be ON for 333mS and OFF for 33mS. 4210-115-60FPM A model 4210 operating from 115V AC with a flash rate of 60 flashes-per-minute (FPM) The load circuit will be ON for 500mS and OFF for 500 mS. ...

Related keywords