80.21.0.240.0000 FINDER, 80.21.0.240.0000 Datasheet - Page 7

ON PULSE TIMER

80.21.0.240.0000

Manufacturer Part Number
80.21.0.240.0000
Description
ON PULSE TIMER
Manufacturer
FINDER

Specifications of 80.21.0.240.0000

Contact Configuration
SPDT
Nom Input Voltage
240V
Delay Time Range
0.1s To 20h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Contact Current Ac Max
16A
Contact Voltage Ac
RoHS Compliant
Timing Adjustment
Screwdriver Slot
Rohs Compliant
Yes
Without signal START
With signal START
Without signal START
With signal START
Functions
Wiring diagram
L
N
K2
N/-
80.11/21/61
N/-
N/-
N/-
N/-
A2
18 15 16
A2
A2
17 18 28
18 15
A2
18 15
A2
18 15
A1
A2
80 82
80.91
80.91
80.82
80.41
N/–
N/–
A2
A2
A1
A1
A1
A1
A1
L/+
L/+
L/+
L/+
L/+
16
B1
16
16
B1
B1
B1
L/+
A1
L/+
A1
S
S
K1
B1
B1
*
**
S
S
• Possible to control an external load, such as another relay coil or timer, connected to the signal start terminal B1.
* With DC supply, positive polarity has to be connected to B1 terminal (according to EN 60204-1).
** A voltage other than the supply voltage can be applied to the command Start (B1), example:
80.11
80.21
80.61
80.82
80.41
80.91
Type
A1 - A2 = 230 V AC
B1 - A2 = 12 V DC
U
U
U
U
S
U
U
S
U
T
T
T
T
T
1
1
T
T
2
T
2
T
T
1
T
T
Tu=(0.05…1)s
T
1
T
t<T
2
T
T
2
t<T
80 Series - Modular timers 6 - 8 - 16 A
t<T
1
t<T
t<T
1
(AI)
Apply power to timer. Output contacts transfer after preset
time has elapsed. Reset occurs when power is removed.
(DI)
Apply power to timer. Output contacts transfer immediately.
After the preset time has elapsed, contacts reset.
(BI)
Apply power to timer (minimum 300ms). Output contacts
transfer immediately. Removal of power initiates the preset
delay, after which time the output contacts reset.
(SD)
Apply power to timer. The star contact ( ) closes immediately.
After preset delay has elapsed the star contact ( ) resets.
After a further transfer time variable from (0.05…1)s the delta
contact ( ∆ ) closes and remains in that position, until reset on
power off.
(BE)
Power is permenently applied to the timer.
The output contacts transfer immediately on closure of the
Signal Switch (S). Opening the Signal Switch initiates the
preset delay, after which time the output contacts reset.
(LI)
Apply power to timer. Output contacts transfer immediately
and cycle between ON and OFF for as long as power is
applied. The ON (T
adjustable.
(LE)
Power is permenently applied to the timer.
Closing Signal Switch (S) causes the output contacts to
transfer immediately and cycle between ON (T
OFF (T
Asymmetrical recycling (ON start).
True OFF delay (power OFF).
ON delay.
ON pulse.
Signal asymmetrical recycling (ON start)
Signal OFF delay.
Star - delta.
2
), until opened.
1
) and OFF (T
2
) times are independently
1
) and
7

Related parts for 80.21.0.240.0000