H3CR-A8E 100-240VAC/100-125VD Omron, H3CR-A8E 100-240VAC/100-125VD Datasheet - Page 6

Solid State Timer

H3CR-A8E 100-240VAC/100-125VD

Manufacturer Part Number
H3CR-A8E 100-240VAC/100-125VD
Description
Solid State Timer
Manufacturer
Omron

Specifications of H3CR-A8E 100-240VAC/100-125VD

Contact Configuration
SPDT
Nom Input Voltage
240VAC
Timing Adjustment
Knob
Relay Mounting
DIN Rail
H3CR-A
Note: The value is ±5% FS +100 ms to –0 ms max. when the C, D, or G mode signal of the H3CR-AP is OFF.
8
Accuracy of
operating time
Setting error
Reset time
Reset voltage
Influence of voltage
Influence of
temperature
Insulation
resistance
Dielectric strength
Impulse withstand
voltage
Noise immunity
Static immunity
Vibration resistance
Shock resistance
Ambient
temperature
Ambient humidity
Life expectancy
EMC
Case color
Degree of protection
Weight
Characteristics
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s)
±5% FS ±50 ms (see note)
Min. power-opening time: 0.1 s max.
Min. pulse width:
10% max. of rated voltage
±0.2% FS max. (±0.2%±10 ms max. in a range of 1.2 s)
±1% FS max. (±1%±10 ms max. in a range of 1.2 s)
100 MΩ min. (at 500 VDC)
2,000 VAC (1,000 VAC for H3CR-AjS), 50/60 Hz for 1 min (between current-carrying metal parts and
exposed non-current-carrying metal parts)
2,000 VAC (1,000 VAC for H3CR-AjS), 50/60 Hz for 1 min (between control output terminals and operating
circuit)
2,000 VAC, 50/60 Hz for 1 min (between contacts of different polarities)
1,000 VAC, 50/60 Hz for 1 min (between contacts not located next to each other)
2,000 VAC, 50/60 Hz for 1 min (between input and control output terminals and operation circuit)
3 kV (between power terminals) for 100 to 240 VAC/100 to 125 VDC, 1 kV for 24 to 48 VAC/12 to 48 VDC
4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to
240 VAC/100 to 125 VDC, 1.5 kV for 24 to 48 VAC/12 to 48 VDC and 24 to 48 VAC/VDC
±1.5 kV (between power terminals) and ±600 V (between no-voltage input terminals), square-wave noise by
noise simulator (pulse width: 100 ns/1 µs, 1-ns rise)
Malfunction: 8 kV
Destruction: 15 kV
Destruction: 10 to 55 Hz with 0.75-mm double amplitude each in 3 directions for 2 hours each
Malfunction: 10 to 55 Hz with 0.5-mm double amplitude each in 3 directions for 10 minutes each
Destruction: 1,000 m/s
Malfunction: 100 m/s
Operating:
Storage:
Operating:
Mechanical: 20,000,000 operations min. (under no load at 1,800 operations/h)
Electrical:
(EMI)
Emission Enclosure:
Emission AC Mains:
(EMS)
Immunity ESD:
Immunity RF-interference from AM Radio Waves:
Immunity RF-interference from Pulse-modulated Radio Waves:
Immunity Conducted Disturbance: IEC61000-4-6:
Immunity Burst:
Immunity Surge:
Light gray (Munsell 5Y7/1)
IP40 (panel surface)
Approx. 90 g
35% to 85%
100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h)
–10°C to 55°C (with no icing)
–25°C to 65°C (with no icing)
2
3 times each in 6 directions
2
3 times each in 6 directions
0.05 s (H3CR-A/-AS)
EN61812-1
EN55011 Group 1 class A
EN55011 Group 1 class A
EN61812-1
IEC61000-4-2:
IEC61000-4-4:
IEC61000-4-5:
6 kV contact discharge (level 3)
8 kV air discharge (level 3)
IEC61000-4-3:10 V/m (80 MHz to 1 GHz)
IEC61000-4-3:10 V/m (900±5 MHz) (level 3)
10 V (0.15 to 80 MHz) (level 3)
2 kV power-line (level 3)
2 kV I/O signal-line (level 4)
1 kV line to line
2 kV line to ground (level 3)
(level 3)
H3CR-A