H3DE-S2 Omron, H3DE-S2 Datasheet - Page 2

TIMER, MULTIFUNCTION

H3DE-S2

Manufacturer Part Number
H3DE-S2
Description
TIMER, MULTIFUNCTION
Manufacturer
Omron
Datasheet

Specifications of H3DE-S2

Contact Configuration
DPCO
Nom Input Voltage
230V
Delay Time Range
0.1s To 120h
Adjustment Type
Screwdriver Slot
Relay Mounting
DIN Rail
Svhc
No SVHC (15-Dec-2010)
Coil Voltage Vac Nom
230V
H3DE-M/-S
Specifications
Note: When the main dial is set to “0” for all settings, the output will operate instantaneously.
Note: 1. DC ripple rate: 20% max.
6
Operating mode
Terminal block
Terminal screw tightening
torque
Input type
Output type
Mounting method
Attachment
Approved standards
x 0.1
x 1
Rated supply voltage
Operating voltage range
Power reset
Reset voltage
Power
consumption
(
(see note 3)
Voltage input
Control output
Ambient temperature
Ambient humidity
(see notes 1 and 2)
General
Time Ranges
Ratings
Time scale display
e sca e d sp ay
2. Since an inrush current of 0.25 A will occur when using the power supply voltage at 24 VDC, pay careful attention when turning on or
3. The power consumption is for mode A after the Timer counts the time-up time and for the AC input at 50 Hz. The power consumption
t 3)
p
off the power supply to the Timer with a solid-state output such as a sensor.
of the H3DE-M
Item
H3DE-M1
H3DE-M2
H3DE-S1
H3DE-S2
0.1 to 1.2 s
1 to 12 s
includes the input circuit with the B1 and A1 terminals short-circuited.
A: ON-delay (Signal or Power)
B: Flicker OFF start (Signal or Power)
B2: Flicker ON start (Signal or Power)
C: Signal ON/OFF-delay
D: Signal OFF-delay
E: Interval (Signal or Power)
G: Signal ON/OFF-delay
J: One-shot (Signal or Power)
Clamps two 2.5 mm
0.98 N m max. {approx. 10 kgf cm max.}
Voltage input
Relay: DPDT
DIN track mounting
Nameplate
UL508, CSA 22.2 No.14
Conforms to EN61812-1 (VDE0435/P2021), IEC60664-1 (VDE0110) 4 kV/2, VDE0106/P100
Conforms to IEC60947-5-1 (AC-13; 250 V 5A/AC-15; 250 V 3 A/DC-13; 30 V 0.1 A)
Conforms to EN50081-1 and EN50082-2
sec
H3DE-M2
24 to 230 VAC/DC (50/60 Hz)
85% to 110% of rated supply voltage
Minimum power-off time: 0.1 s
2.4 VAC/DC max.
AC: approx. 4.3 VA (2.2 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 4.8 VA (2.4 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
AC: approx. 2.7 VA (1.6 W) at 230 VAC
DC: approx. 0.7 W at 24 VDC
AC: approx. 3.2 VA (1.9 W) at 230 VAC
DC: approx. 1.0 W at 24 VDC
Max. permissible capacitance between input lines (terminals B1 and A2) : 2000 pF
Load connectable in parallel with inputs (terminals B1 and A2)
H-level:
L-level:
Contact output: 5 A at 250 VAC with resistive load (cos = 1)
Operating:–10 C to 55 C (with no icing)
Storage: –25 C to 65 C (with no icing)
Operating: 35% to 85%
20.4 to 253 VAC/DC
0 to 2.4 VAC/DC
2
max. bar terminals without sleeves.
0.1 to 1.2 min
1 to 12 min
5 A at 30 VDC with resistive load (cos = 1)
Relay: SPDT
min
H3DE-M1
Time unit display
0.1 to 1.2 h
1 to 12 h
A: ON-delay
B2: Flicker ON start
E: Interval
J: One-shot
---
Relay: DPDT
hrs
H3DE-S2
1 to 12 h
10 to 120 h
Relay: SPDT
H3DE-M/-S
H3DE-S1
10 h

Related parts for H3DE-S2