H3DE-H Omron, H3DE-H Datasheet

Solid State Timer

H3DE-H

Manufacturer Part Number
H3DE-H
Description
Solid State Timer
Manufacturer
Omron
Datasheet

Specifications of H3DE-H

Contact Configuration
SPCO
Nom Input Voltage
230V
Timing Adjustment
Screwdriver Slot
Relay Mounting
DIN Rail
Length/height, External
79mm
Voltage Ac
250V
External Width
22.5mm
Voltage Rating Vdc
30V
• Two delay-time models available.
• Covers wide range of supply voltage.
Model Number Structure
■ Model Number Legend
Ordering Information
■ List of Models
■ Accessories (Order Separately)
1. H: Power OFF-delay timer
Note: Specify both the model number and supply voltage when ordering.
100 to 120 VAC
200 to 230 VAC
24 VAC/VDC
48 VAC/VDC
Mounting Track
End Plate
Spacer
H3DE -
0.1 to 12 seconds (S Series)
1 to 120 seconds (L Series)
Solid-state Power OFF-delay Timer
H3DE-H
Example: H3DE-H 24 VAC/DC S
1
Supply voltage
50 cm (l) x 7.3 mm (t)
1 m (l) x 7.3 mm (t)
1 m (l) x 16 mm (t)
PFP-M
PFP-S
Time span code
Supply voltage
H3DE-H
PFP-50N
PFP-100N
PFP-100N2
S Series (time range: 0.1 to 12 s)
Solid-state Power OFF-delay Timer
Model
H3DE-H
L Series (time range: 1 to 120 s)
H3DE-H
B-75

Related parts for H3DE-H

H3DE-H Summary of contents

Page 1

... List of Models Supply voltage 100 to 120 VAC 200 to 230 VAC 24 VAC/VDC 48 VAC/VDC Note: Specify both the model number and supply voltage when ordering. Example: H3DE-H 24 VAC/DC S ■ Accessories (Order Separately) Mounting Track 50 cm (l) x 7 (l) x 7 (t) End Plate ...

Page 2

... DC: Approx. 0 VDC AC: Approx. 0 120 VAC AC: Approx. 1 230 VAC Contact output 250 VAC with resistive load (cos = VDC with resistive load (cos = 1) Operating (with no icing) Storage (with no icing) Operating: 35% to 85% H3DE-H Min. power ON time 0.1 s minimum 0.3 s minimum ...

Page 3

... EN55011 Group 1 class A EN55011 Group 1 class A EN61000-3-2 EN61000-3-3 EN61812-1 EN61000-4- contact discharge (level 3) EN61000-4- power port and output port (level 3) EN61000-4- common mode (level 3) Solid-state Power OFF-delay Timer 8 kV air discharge (level control port with capacitive clamp (level differential mode (level 3) H3DE-H B-77 ...

Page 4

... Timer is turned OFF and the output of the Timer is turned OFF when the preset time elapses. ■ Terminal Arrangement Note: DC supply voltage does not require the designation of polarity. B-78 Solid-state Power OFF-delay Timer Indicator Time scale circuit selector Oscillation Counting circuit circuit (DIN notation H3DE-H Output circuit ...

Page 5

... Lit when the Timer is turned ON. Time Setting The operating time of the Timer is set with the time setting dial. Time setting dial Nameplate for user use (20 x 5.4 mm white panel) Time setting dial (for setting power OFF-delay time) (Front View) Solid-state Power OFF-delay Timer H3DE-H B-79 ...

Page 6

... Dimensions H3DE-H B-80 Solid-state Power OFF-delay Timer Terminal block (black) Terminal block (black) H3DE-H Surface color: Light gray 5Y7/1 (OMRON) ...

Page 7

... Accessories (Order Separately) (Common) Note: The undermentioned is common for all H3DE models. Note: All units are in millimeters unless otherwise indicated. ■ Dimensions Mounting Track PFP-100N, PFP-50N 4 Length 1 m PFP-100N 50 cm PFP-50N 1 m PFP-100N2 End Plate PFP pan head screw PFP-100N2 7 ...

Page 8

... For the power supply of an input device, use an isolating transformer, of which the primary and secondary windings are mutually isolated (B) and the secondary winding is not grounded. The H3DE-H has a large inrush current; provide sufficient power supply capacity. If the power supply capacity is too small, there may be delays in turning ON the output min. ...

Page 9

... Pay particular attention when using shielded cables. ■ Wiring (H3DE-H) The H3DE has a high impedance circuit. Therefore, the H3DE may not be reset if the H3DE is influenced by inductive voltage. In order to ...

Page 10

... Operation (H3DE-H) An interval minimum is required to turn on the H3DE after the H3DE is turned off. If the H3DE is turned on and off repeatedly with an interval of shorter than 3 s, the internal parts of the H3DE may deteriorate and the H3DE may malfunction min. Power Output state 1 ...