24SWUDC AMPERITE, 24SWUDC Datasheet

TIME DELAY RELAY, DPDT, 77.5H, 24V

24SWUDC

Manufacturer Part Number
24SWUDC
Description
TIME DELAY RELAY, DPDT, 77.5H, 24V
Manufacturer
AMPERITE
Datasheet

Specifications of 24SWUDC

Contact Configuration
DPDT
Nom Input Voltage
24V
Delay Time Range
0.1s To 77.5h
Timing Adjustment
DIP Switch, Knob
Relay Mounting
Plug In
Time Range Max
77.5h
No. Of Poles
2
Brand/series
SWUDC Series
Contact Form
DPDT-NO⁄NC
Current, Rating
10, 15 A
Function
Timing
Mounting Type
PCB
Number Of Pins
11
Relay Type
Solid State
Standards
UL, CSA
Temperature, Operating, Maximum
70 °C
Temperature, Operating, Minimum
-45 °C
Termination
Plug-In
Timer Type
Multi-Function
Timing Range
72 to 360 sec.
Voltage, Control
24 VAC⁄VDC
Voltage, Rating
120, 240⁄30 VAC⁄VDC
Timing Mode:
The SWUDC Series time delay relay operates in any one of four timing modes, user
selected by means of 2 sections (S8, S9) of a 9 position Dip Switch (the other 7 sections
control timing). These modes are as follows: Delay on operate, delay on release, delay on
operate and release, interval or one-shot. An external switch may be used to provide
trigger control of the time delay cycle.
Timing Diagrams & Modes:
Delay On Operate:
Two operation methods:
1) With external switch closed: delay on operate timing cycle begins upon application of
input power. The relay contacts transfer at the end of the delay period and will remain
transferred until input voltage is removed. Reset occurs when input voltage is removed.
2) With external switch open: delay on operate timing cycle begins after the application
of input power and the closure of the external switch. Upon switch closure the relay
contacts transfer at the end of the delay period and will remain transferred until the input
voltage is removed. Reset occurs when input voltage is removed.
Delay On Release:
Two operation methods:
1) With external switch closed: Upon application of input voltage relay contacts transfer
SWUDC
Series
TDR
Solving your relay requirements since 1922
… Solid state CMOS digital circuitry
… Four timing modes: Delay on operate; delay on release;
delay on operate & release; and interval or one-shot
… DPDT (2 form C) isolated 10 ampere relay contacts
… Timing selection: Binary coded Dip Switch with knob
adjustable potentiometer
… User selectable timing ranges covering 0.1 secs. to 77.5
hours.
… UL File #E96739 (M)
… CSA File #LR62586
West New York, NJ 07093
www.Amperite.com
567 52nd Street
(800) 752-2329
Amperite Co.
P.O. Box 329

Related parts for 24SWUDC

24SWUDC Summary of contents

Page 1

... Reset occurs when input voltage is removed. Delay On Release: Two operation methods: 1) With external switch closed: Upon application of input voltage relay contacts transfer Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 ...

Page 2

... When the timing cycle is completed the relay contacts will release. The timing cycle may be reset to zero during the timing cycle by removing input power. Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www ...

Page 3

... Input Information: Voltage: 12V - AC or DC, 24V - AC or DC, 48V DC, 110V DC, 120V AC. Other voltages available. Power Requirement: AC inputs less, DC inputs: 3 Watts or less. Transient Protection: 1 JOULE MOV Polarity Protection inputs - Yes Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com ...

Page 4

... This custom timing range is knob adjustable with a 5:1 vernier control. How To Select A Time Delay: 1) Determining The Appropriate Timing Range Set Dip Switch positions S1 & follows for the four basic timing ranges. Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www ...

Page 5

... C) The multiplier is equal to 1/2 of this quotient - 180/10 = 18. 18 therefore the multiplier for 180 seconds is 9 and the user must set switches S3 follows Off On Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www.Amperite.com ...

Page 6

... User will have a time delay range of 72 secs - 360 secs. SWUDC Timing Mode Operating Instructions: The Amperite SWUDC Time Delay Relay operates in any one of four modes. These are user selectable by means of setting S8 and S9 of the nine positions Dip Switch. The modes and switch positions are as follows: ...

Page 7

... Close External Switch. Apply power. Relay contacts transfer immediately. At the end of the delay time the relay contacts release. Ordering Information: Definition of a part number for the Amperite SWUDC Series Time Delay Relay. Example: A: Denotes nominal input voltage. Voltages Available: 12V - AC or DC, 24V - AC or ...

Page 8

... D: Denotes DPDT (2 form C) 10 ampere CMOS four timing mode SWUDC Series Time Delay Relay with binary coded nine position Dip Switch & built in potentiometer. Solving Your Timing Requirements Since 1922 Amperite Co. 567 52nd Street P.O. Box 329 West New York, NJ 07093 (800) 752-2329 www ...

Related keywords