84134030 Crouzet USA, 84134030 Datasheet

SSR, PANEL MOUNT, 280VAC, 32VDC, 75A

84134030

Manufacturer Part Number
84134030
Description
SSR, PANEL MOUNT, 280VAC, 32VDC, 75A
Manufacturer
Crouzet USA
Datasheets

Specifications of 84134030

Control Voltage Range
3VDC To 32VDC
Operating Voltage Range
24VAC To 280VAC
Load Current
75A
Isolation Voltage
4000Vrms
Control Voltage Type
DC
Relay Terminals
Screw
Output Device
SCR
Load Voltage Rating
24 VAC to 280 VAC
Load Current Rating
75 A
Relay Type
Hockey Puck
Turn-on Switching
Zero Voltage
Brand/series
GN Series
Contact Form
SPST-NO
Current, Rating
75 A
Function
Zero-Switching
Mounting Type
Panel
Number Of Pins
4
Standards
UL⁄cUL, CSA, CE, TUV
Termination
Screw
Voltage, Control
32 VDC
Voltage, Rating
280 VAC
Load Voltage Max
280VAC
Rohs Compliant
Yes
Control Voltage Max
32V
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Voltage range (Vrms)
Peak Voltage (Vpk , t = I min.)
Off-state leakage
(@ max. line voltage & Ta = 25ºC)
Output Current (Mounted on
proper heat sink, see deratings)
Minimum Current (mArms)
1 cycle surge current (50 Hz)
1 cycle surge current (60 Hz)
1 second surge current
(Apk, Ta = 25ºC) 50/60 Hz
Forward voltage drop
(Vpk @ Imax, Ta = 25ºC)
I
I
Rjb (thermal res. Junction to
baseplate, ºC/W)
Static off-state dv/dt
(Vµs, Ta = 25ºC)
Minimum heat sink @ ambient
(for max current = ºC/W & Ta)
Input voltage*
Drop out voltage
Max. input current
Min. input current (for on-state)
Input Resistance
Turn-on time**
Turn-off time
* 4-32Vdc for 48-660Vac models
** Random SSR's turn on in less than 100µs
Operating Temperature (ºC)****
Storage Temperature (ºC)
Input to output isolation
Input/output to ground isolation
Input to output capacitance
Operating Frequency
Housing Material
CE Compliant with the LVD 73/23/EEC
UL / cUL Recognized per UL 508 and CSA C22.2 no. 14-M91
TUV EN60950
IEC 1000-4-2: Electrostatic Discharge - Level 3
IEC 1000-4-3: Radiated Electromagnetic Noise - Level 3
IEC 1000-4-4: Electrically Fast Transients - Level 3
IEC 1000-4-5: Electrical Surges - Level 3
IEC 1000-4-6: Conducted Electromagnetic Noise - Level 3
CISPR 11 - Class A: Allowable Levels of Conducted and Radiated Noise
for Industrial Environments
*** For ambient temperatures above 40°C the maximum control voltage
**** Increase minimum input voltage by 1 Vdc for operation from -20° to -40°C
GN SERIES SOLID STATE RELAYS
Output Specifications
Input Specifications
General Characteristics
Safety and Noise Immunity Compliance
2
2
T (50Hz, ½ cycle)
T (60Hz, ½ cycle)
must not exceed 250Vac
Order/Technical Support - Tel: (877) 502-5500 / Fax: (619) 710-8540 / www.crouzet-usa.com
3.0 @
70ºC
1.35
150
175
110
120
500
0.5
10
50
50
3-32Vdc
8.33ms
8.33ms
1 Vdc
14mA
7mA
-20 to + 80
-40 to + 100
4000Vrms
2500Vrms
8pF (typical)
47 to 63 Hz
UL 94V0 (self extinguishing)
1.5 @
50ºC
24 - 280Vac
1.35
275
300
380
370
500
0.4
25
50
85
0.1mArms
Products and specifications subject to change without notice
600
Current Regulated
1.0 @
2520
2320
40ºC
1.35
0.25
100
710
750
150
500
50
18-36Vac
16mArms
2 Vrms
20ms
30ms
0.7 @
0.155
1050
1100
5500
5000
40ºC
100
225
500
1.3
75
0.5 @
0.155
1120
1200
6270
6000
40ºC
90-280Vac***
100
100
300
500
48 - 660Vac
1.3
0.25mArms
10mArms
10 Vrms
5mArms
20ms
30ms
1200
12800
12050
0.4 @
1600
1700
40ºC
0.15
125
100
375
500
1.3
10 Amp
25 Amp
50 Amp
75 Amp
100 Amp
125 Amp
10 Amp
25 Amp
50 Amp
75 Amp
100 Amp
125 Amp
For 18-36Vac control replace the last digit in the part number
with a 2.
Part Numbers
(Zero Crossing)
Random SSR's
Rating
Rating
Example: 84134012
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
24-280Vac
48-660Vac
Output
Output
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
90-280Vac
3-32Vdc
90-280Vac
4-32Vdc
3-32Vdc
4-32Vdc
3-32Vdc
4-32Vdc
3-32Vdc
4-32Vdc
3-32Vdc
4-32Vdc
3-32Vdc
4-32Vdc
3-32Vdc
4-32Vdc
Input
Input
84 134 001
84 134 000
84 134 101
84 134 100
84 134 011
84 134 010
84 134 111
84 134 110
84 134 021
84 134 020
84 134 121
84 134 120
84 134 031
84 134 030
84 134 131
84 134 130
84 134 041
84 134 040
84 134 141
84 134 140
84 134 081
84 134 080
84 134 181
84 134 180
84 134 200
84 134 300
84 134 210
84 134 310
84 134 220
84 134 320
84 134 230
84 134 330
84 134 240
84 134 340
84 134 280
84 134 380
IP00
IP00
84 137 001
84 137 000
84 137 101
84 137 100
84 137 011
84 137 010
84 137 111
84 137 110
84 137 021
84 137 020
84 137 121
84 137 120
84 137 031
84 137 030
84 137 131
84 137 130
84 137 041
84 137 040
84 137 141
84 137 140
84 137 081
84 137 080
84 137 181
84 137 180
84 137 200
84 137 300
84 137 210
84 137 310
84 137 220
84 137 320
84 137 230
84 137 330
84 137 240
84 137 340
84 137 280
84 137 380
IP20
IP20

Related parts for 84134030

84134030 Summary of contents

Page 1

... GN SERIES SOLID STATE RELAYS Output Specifications Voltage range (Vrms) Peak Voltage (Vpk , min.) Off-state leakage (@ max. line voltage & 25ºC) Output Current (Mounted on 10 proper heat sink, see deratings) Minimum Current (mArms cycle surge current (50 Hz) 150 1 cycle surge current (60 Hz) ...

Page 2

DIMENSIONS IN INCHES IP00 2.250 .275 1.700 .183 LED INPUT 1.000 .445 .442 1.875 DERATING CURVES DERATE CURVES: GN SSR-10 AMP TRIAC OUTPUT Ambient Temperature (°C) Order/Technical Support – Tel: (877) 502-5500 / FAX: (619) 710-8540 / www.crouzet-usa.com 1/4 .249 ...

Page 3

DERATE CURVES: GN SSR-10 AMP SCR OUTPUT Ambient Temperature (°C) DERATE CURVES: GN SSR-50 AMP SCR OUTPUT (1200 & 600V) Ambient Temperature (°C) DERATE CURVES: GN SSR-100 AMP SCR OUTPUT (1200 & 600V) Ambient Temperature (°C) Products and specifications subject ...