Specifications of HW1A-B1-B

Actuator / Cap Color
Black
For Use With
YS Series IEC Contactors
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
www.idec.com
Surge Suppressor
Relay Interface Module
Star (Wye) Delta Timer
Replacement Coils
Accessory
# — YS9Z-KIL70519* is available ONLY in 110V (D110) or 220V (D220) models.
IEC Contactors
Type
RC Circuit
Varistor
Isolates the coil of contactor from PLC output by provid-
ing an easy to mount module that takes 24V DC input and
switches up to 380V AC for contactor coils.
External source required for contactor coil.
Input Voltage
100V AC to
240V AC
50/60 Hz
AC Coils for AC Contactors
For use with YS-9F through YS-12F
For use with YS-20F through YS-25F
For use with YS-32F to YS-38F
For use with YS-40F to YS-65F
For use with YS-80F to YS-125F
For use with YS-150F to YS-180F
For use with YS-220F to YS-300F
DC Coils for DC Contactors 9F through 65F
For use with YS-9F through YS-25F
For use with YS-32F through YS-38F
For use with YS-40F through YS-65F
DC Coils for DC Contactors 80F through 125F
For use with YS-80F through YS-125F #
AC/DC Module for 80F through 125F DC coils only
100V AC/DC Module for YS-80F through YS-125F
200V AC/DC Module for YS-80F through YS-125F
USA: (800) 262-IDEC or (408) 747-0550, Canada: (888) 317-IDEC
50-127V AC
110-240V AC
50-127V AC
110-240V AC
380-440V AC
Star: Delayed SPST-NO
Delta: Delayed SPST-NO
Star: Delayed SPST-NO
Delta: Delayed SPST-NO
Instantaneous SPST-NO
Rated Voltage
Contact Style
Description
Accessories, continued
11-pin
11-pin
8-pin
8-pin
YS9Z-KIL70461-*
YS9Z-KIL70462-*
YS9Z-KIL70463-*
YS9Z-KIL70464-*
YS9Z-KIL70518-*
YS9Z-KIL70466-*
YS9Z-KIL70467-*
YS9Z-KIL70562-*
YS9Z-KIL70564-*
YS9Z-KI411880-*
YS9Z-KIL70519-*
YS9Z-KIFCA840546A
YS9Z-KIFCA840546B
YS9Z-TU*C120
YS9Z-TU*C240
YS9Z-TU*V120
YS9Z-TU*V240
YS9Z-TU*V440
YS9Z-TCU500UH*
GT3S-1AF20
GT3S-1EAF20
GT3S-2AF20
GT3S-2EAF20
Part Number
25 = YS-9F to YS-25F
65 = YS-32F to YS-65F
125 = YS-80F to YS-125F
180 = YS-150F to YS-180F
300 = YS-220F to YS-300F
12 = YS-9F to YS-12F
25 = YS-20F- to YS-25F
38 = YS-32F to YS-38F
65 = YS-40F to YS-65F
125 = YS-80F to YS-125F
180 = YS-150F to YS-180F
300 = YS-220F to YS-300F
See Section G for further
information
A024 = 24V AC 50/60 Hz
A048 = 48V AC 50/60 Hz
A120 = 120V AC 50/60 Hz
A240 = 240V AC 50/60 Hz
A380 = 380V AC 50/60 Hz
A480 = 480V AC 50/60 Hz
A600 = 600V AC 50/60 Hz
D024 = 24V DC
D048 = 48V DC
D110 = 110V DC
D220 = 220V DC
D110 = 110V DC
D220 = 220V DC
Used in conjunction with
YS9Z-KIL-70519-* for DC coils
80F through 125F only.
* Applicable Size Codes