A165E-01 Omron, A165E-01 Datasheet - Page 8

CONTACT BLOCK, SPST-NC, 5A, SOLDER

A165E-01

Manufacturer Part Number
A165E-01
Description
CONTACT BLOCK, SPST-NC, 5A, SOLDER
Manufacturer
Omron
Datasheets

Specifications of A165E-01

No. Of Poles
1
Contact Current Max
5A
Contact Voltage Ac Max
250V
Contact Voltage Dc Max
30V
Switch Terminals
Solder
Circuitry
SPST-NC
For Use With
A165E Series Emergency Stop Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Installation
Mounting to the Panel (Models with Separate Construction)
After installing the Operation Unit, snap in the Switch from the back of the panel.
Attach rubber packing or the Yellow Plate
onto the Switch from its terminal side.
Insert the Switch into the panel from the
front. Install the lock ring and mounting
nut from the terminal side and tighten.
Adjust the slits on the hole of rubber
packing and Yellow Plate to the
protruding part of the Unit.
Rubber packing is not necessary when
the Yellow Plate is used.
Tighten the nut to the torque of 0.29 to
0.49 N·m.
Casing should be installed with its
protruding part adjusted to the slit of the
panel hole.
Align the lock ring to the groove of the
casing so that the edge is drawn to the
panel side.
Snap on the Switch to the Operation Unit.
Make sure that the Switch has the correct orientation when snapping it onto the
Operation Unit.
Align the white dot on the Operation Unit with the guide groove on the side of
the Switch marked with an “L” as shown below, and push the Switch into the
Operation Unit until it clicks into place. Confirm that the Switch is securely in
place before using.
When mounting the Lamp, make sure it is facing the direction shown in the
following diagram. Insert the Lamp while matching the protruding part of the
Lamp and the small guides on the outer surface of the casing.
Protruding part
(4) Installing the LED Lamp
http://www.ia.omron.com/
(2) Mounting the Switch
White dot
Wide guide
Lock hole
Guide groove
Narrow guide
Cutout
Lock
(1) Installing the Operation Unit
L marking
Mounting nut
Rubber packing
(included with the
product) or Yellow
Plate (sold separately)
Lock ring
Panel
Insert the prongs of the A16Z-5080 Extractor between the Switch and the
Operation Unit, grip the Switch, and pull to remove.
(c)Copyright OMRON Corporation 2007 All Rights Reserved.
(3) Removing the Switch
Extractor (A16Z-5080)
Rubber packing or Yellow Plate (sold separately)
Panel
Edge
Mounting nut
Lock ring
A165E
8