HW9Z-LS IDEC, HW9Z-LS Datasheet - Page 11

no-image

HW9Z-LS

Manufacturer Part Number
HW9Z-LS
Description
FINGER GUARD
Manufacturer
IDEC
Datasheet

Specifications of HW9Z-LS

For Use With
HW Series Switches
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Replacement of Lamps
Lamps can be replaced by using the lamp holder tool (OR-
55) from the front of the panel, or by removing the contact
block assembly from the operator unit.
[How to Remove]
1. To remove, slip the lamp
[How to Install]
1. To install, insert the lamp head into the lamp holder tool,
2. Place the pins on the lamp
About Pushbutton Switches
Narrow Mounting
When mounting the units closely in a horizontal row on
30mm centers, use optional barriers to prevent interconnec-
tion between adjoining terminals. The barriers can be
attached simply by pressing them onto the sides of contact
blocks.
The pushbuttons cannot
be removed or replaced!
Do not attempt to remove
using a flat screwdriver or
pincers, otherwise the
pushbuttons may be dam-
aged.
When mounting transformer
type illuminated units closely
in a horizontal row on 30-mm
centers, insert solid wires or
stranded wires into inside of
the terminal screw on the
transformer (see figure on the
right) to prevent short circuit
between adjoining terminals.
Removing the Lamps from the Front of the Panel
Instructions
holder tool onto the lamp
head lightly. Then push
slightly, and turn the lamp
holder tool counterclock-
wise.
and hold the lamp as shown in the figure below.
base to the grooves in the
lamp socket. Insert the
lamp and turn it clockwise.
Lamp
Lamp Holder Tool
Pushbuttons
X1
Inside Inside
30
X2
Barrier
X1
30
Do not attempt
to remove the
pushbuttons!
Lamp Base
X2
Tightening Torque for Terminal Screws
Tighten the M3.5 terminal screws to a torque of 1.0 to 1.3
N·m
Installation of LED Illuminated Units
When using full voltage type LED illuminated units, provide
protection against electrical noise, if necessary.
Applicable Wiring
The applicable wire size is 2 mm
mm maximum) One or two wires can be connected.
Be sure to use an insulation tube or cover on the crimping
part of the crimping terminal to prevent electrical shocks.
Note: When connecting wires to contact blocks or transformers in
Installing the Rubber Boot
When using the HW7D pushbuttons in places where the
pushbuttons are subjected to water splash or an excessive
amount of dust, make sure to use the HW9Z-D7D rubber
boot (IP65) which is ordered separately.
Remove the gasket from the operator, and install the rubber
boot on the operator. Pull out the seals of the rubber boot
and place them around the operator sleeve as shown. Make
sure that the seals are not twisted or tucked inside and that
the gasket does not remain, otherwise the normal water-
proof and dustproof characteristics are not ensured.
Applicable Crimping Terminal
Solid Wire
Notes for Installing the Rubber Boot
Remove the gasket.
.
the direction shown below, keep the insulation stripping
length 6.6 mm at the maximum.
Gasket
HW
Remove
Series
4 max.
Install the rubber boot
on the pushbuttons.
Seals
Instructions
Seals
ø3.6 min.
2
8 max.
maximum. (solid wire ø1.6
Install
5.5 min.
X1
X2
Rubber boot is
installed.
ø22
11

Related parts for HW9Z-LS