704.963.6 EAO, 704.963.6 Datasheet - Page 84

Switch Legend Plate

704.963.6

Manufacturer Part Number
704.963.6
Description
Switch Legend Plate
Manufacturer
EAO
Series
04r
Datasheet

Specifications of 704.963.6

Label Size
60mm Dia
Diameter
60mm
Legend
Emergency Stop
Label Type
Warning
Background Color
Yellow
For Use With
04 And 84 Series Emergency Stop Pushbuttons
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Technical Data
0
Electrical characteristics
Electrical characteristics for AC
0
0
Number of stages
1 to 8 positions max.
Number of contacts
1 to 16 max. normally open contacts
(contact positioning according circuit drawing)
Switching angle
Basic position of switching position "a" is 9 o'clock
Maintained action
12 max.
8 max.
6 max.
4 max.
Momentary action with release 24 °
(provide at the beginning or at the end )
Standard type of Kraus & Naimer
CG4 Hard Silver contacts with 1 μm Gold layer
CG4-1 Hard Silver contacts with 35 μm Gold layer
Minimum Voltage
20 V
Rated Impulse Withstand Voltage U
4 kV
Short Circuit Protection
Max. fuse size (gL- characteristic) 10 A
Rated short-time withstand current (1s-current) 90 A
Standards
The devices comply with : EN IEC 60947-3, VDE 0660 part 107
Rated Operational Voltage U
440 V
Rated Insulation Voltage U
440 V
Rated Thermal Current I
10 A
Rated Operational Current I
AC-15 Switching of control devices, contactors, valves etc.
110 V - 120 V
220 V - 240 V
380 V - 440 V
No load operation
10 A
AC-21A Switching of resistive loads, including moderate overloads
For switchin of power >1 kW
10 A
AC-22A Switching of combined resistive or low inductive loads
including moderate overloads
220 V - 240 V
Rated Utilization Category
AC-2 Slip ring motor starting, reversing and plugging, star-delta
starting 3 phase, 3 pole
82
07.2010
2.5 A
2.5 A
1.5 A
10 A
Switching angle
30 °
45 °
60 °
90 °
u
/I
th
i
e
e
imp
0
0
0
0
Electrical characteristics for AC (UL/Canada)
0
Electrical characteristics for DC
0
220 V - 240 V
380 V - 440 V
AC-3 Direct-on-line starting, star-delta starting
3 phase, 3 pole
1 phase, 2 pole
AC-Direct-on-line starting, reversing, plugging and inching
3 phase, 3 pole
1 phase, 2 pole
AC-23A Frequent switching of motors or other high inductive loads
3 phase, 3 pole
1 phase, 2 pole
Overvoltage category
III, valid for lines with grounded common neutral termination
Degree of pollution
3, valid for lines with grounded common neutral termination
Rated operational voltage
300 V
Rated Insulation Voltage U
300 V
Rated Thermal Current
10 A
Ampere Rating
Resisitve or low inductive loads, for switching of power >1 kW, 10 A
Ratings
Standard motor load, DOL Rating (similar AC-3)
3 phase, 3 pole
1 phase, 2 pole
Pilot Duty, Heavy
300 VAC
Switch Rating DC
Resistive loads T ≤1 ms
Number of series contact(s)
1
24 V
2
48 V
3
70 V
2.5 kW
4.5 kW
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
380 V - 440 V
110 V - 120 V
220 V - 240 V
110 V - 120 V
220 V - 240 V
277 V - 277 V
4
95 V
i
5
120 V 145 V 190 V 10 A
2.5 kW
2.2 kW
0.3 kW
0.55 kW
0.75 kW
0.37 kW
0.55 kW
0.15 kW
0.25 kW
0.5 kW
1.8 kW
3 kW
0.37 kW
0.75 kW
1.1 kW
0.75 HP
1 HP
0.33 HP
0.75 HP
0.75 HP
6
8
Switch
Capacity
04

Related parts for 704.963.6