D6F-V03A1 Omron, D6F-V03A1 Datasheet - Page 8

AIRFLOW SENSOR 0-3 M/SEC 3.3V

D6F-V03A1

Manufacturer Part Number
D6F-V03A1
Description
AIRFLOW SENSOR 0-3 M/SEC 3.3V
Manufacturer
Omron
Series
D6Fr
Type
MEMS Air Flow Sensorr
Datasheets

Specifications of D6F-V03A1

Sensing Range
0 ~ 3 m/s
Flow Sensor Type
Air
Voltage - Input
3.15 ~ 3.45 V
Port Size
2mm x 3mm
Material - Body
Thermoplastic resin
Sensor Type
MEMS Air Flow
Rated Range
0 M/s to 3 M/s
Accuracy/reliability
+/- 10 % Full Scale
Analog Output
0 V to 2 V
Supply Voltage
3.3 V
Accuracy
± 10%
Flow Range
0 - 3 M/s
Output Type
Analog
Output Voltage Max
2V
Body Material
Thermoplastic Resin
Flow Rate Min
0GPM (US)
No. Of Ports
2
Sensor Output
Analog
Accuracy %
10%
Sensor Body Material
Thermoplastic Resin
Rohs Compliant
Yes
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Switch Function/rating
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
D6FV03A1
Z2629
Mass Flow Sensors
D6F-10A5 / 20A5 / 50A5-10A6 / 20A6 / 50A6
High accuracy mass flow sensor
Our D6F-W and D6F-V
Sensors incorporate a
Dust Segregation System
(DSS) that helps maintain
sensing performance in a
variety of applications.
Air Velocity Sensors
Dust Segregation System (D6F-W)
Flow Range
Compact Size
Supply Voltage
Analogue Output
Accuracy
Temp Range
Gas Type
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0.0
D6F-10A5/10A6-000
Operating Characteristics
2.0
Flow rate(L/min)
4.0
6.0
8.0
10.0
10LPM (D6F-10A5/10A6-000), 20LPM (D6F-20A5/20A6-000)
50LPM (D6F-50A5/A6-000)
78(L) x 30(W) x 30 (H)mm
10.8 - 26.4VDC
1 to 5V
+/- 3% F.S.
-10 to +60°C
Air
The housing design is based on a centrifugal principle to segregate
particulates from the air. Most particulates cannot pass through the sensing
area and are discharged through the exhaust route. As a result of the
numerical analysis, the efficiency of the Dust Segregation System separates
up to 99.5% of dry particulates.The D6F-W01A1 and D6F-W04A1 airflow
sensors can measure air velocity from 0-1m/s and 0-4m/s with an
accuracy of +/-5% full scale deflection. The D6F-V03A1
measures 0-3m/s. Each is supplied as standard,
optimally adjusted at the factory so easy and rapid
user application is guaranteed.
6.0
5.0
4.0
3.0
2.0
1.0
0.0
0.0
D6F-20A5/20A6-000
Operating Characteristics
4.0
Flow rate(L/min)
8.0
12.0
16.0
Perf
20.0
A5 type
6.0
5.0
4.0
3.0
2.0
1.0
0.0
A6 type
0.0
D6F-50A5/50A6-000
10.0
Operating Characteristics
Flow rate(L/min)
20.0
30.0
40.0
50.0

Related parts for D6F-V03A1