D6F-05N2-000 Omron, D6F-05N2-000 Datasheet

SENSOR GAS FLOW TYPE 0-5LTR METL

D6F-05N2-000

Manufacturer Part Number
D6F-05N2-000
Description
SENSOR GAS FLOW TYPE 0-5LTR METL
Manufacturer
Omron
Series
D6Fr
Type
MEMS Mass Flow Sensorr
Datasheets

Specifications of D6F-05N2-000

Supply Voltage
12 V to 24 V
Sensing Range
0 ~ 1.32 GPM (0 ~ 5 LPM)
Flow Sensor Type
Liquid
Voltage - Input
10.8 ~ 26.4 V
Port Size
Rc 1/4", 0.25" (6.35mm)
Material - Body
Aluminum
Sensor Type
MEMS Mass Flow
Rated Range
0 L/min to 5 L/min
Accuracy/reliability
+/- 3 % Full Scale
Analog Output
1 V to 5 V
Accuracy
± 3%
Port Style
Straight
Length/height, External
22.1mm
Flow Range
0-5L/min
External Width
62mm
Output Voltage Max
5.7VDC
Supply Voltage Max
26.4VDC
Flow Rate Min
0GPM (US)
External Depth
21.6mm
Rohs Compliant
Yes
No. Of Ports
2
Supply Voltage Min
10.8VDC
Operating Temperature Max
60°C
Sensor Output
Analog
Air Volume
5l/min
Accuracy %
3%
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Switch Function/rating
-
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
D6F05N2000
Z1673
For LPG and LNG Applications.
Metal Body.
Ordering Information
Note:
Absolute Maximum Ratings
Performance
Note:
RoHS Compliant
Power supply voltage
Output voltage
Item
Flow rate
Joints
Case material
Operat-
ing
condi-
tions
Power supply voltage
Output signal
Current consumption
Insulation resistance
Withstand voltage
Measures gas flow of 1 to 5 L/min.
High accuracy of ±3 FS.
Flow rates can be measured without being
affected by temperature or voltage.
MEMS Flow Sensor
Appearance
The fluid must be clean, dry gas, with no dust or oil mist.
“L/min (normal)” is the volume flow rate at 0
Applicable fluid City gas (13A)
Max. allowable
pressure
Operating tem-
perature
Operating hu-
midity
Storage tem-
perature
Storage humid-
ity
Item
Model number
Aluminum alloy
Vcc
Vout
Re 1/4 thread
Aluminum alloy
(The fluid must be clean, dry gas, with no dust or oil mist.)
200 kPa
−10 to 60°C (with no condensation or icing)
85% max. (with no condensation or icing)
−40 to 80°C (with no condensation or icing)
85% max. (with no condensation or icing)
10.8 to 26.4 VDC
Analog output, 1 to 5 VDC (non-linear output)
Without load: Vcc = 12 to 24 VDC, Vss = 0 V, 25°C, 15
mA max.
Between Sensor outer cover and lead terminals: 20 MΩ
min. (at 500 VDC)
Between Sensor outer cover and lead terminals: 500
VAC, 50/60 Hz min. for 1 min (leakage current: 1 mA
max.)
0 to 1 L/min (nor-
mal) (See note.)
Case
D6F-01N2-000
Symbol
LPG (See note.)
City gas (13A) (See note.)
26.4
6
Rating
Applicable fluid
0 to 5 L/min (nor-
mal) (See note.)
D6F-05N2-000
°
C and 101.3 kPa.
VDC
VDC
Unit
0 to 2 L/min (nor-
mal) (See note.)
LPG
D6F-02L2-000
0 to 1 L/min
0 to 5 L/min
0 to 2 L/min
Measured flow rate
range
Connections
D6F-01N2-000
D6F-05N2-000
D6F-02L2-000
Pin No.
Connectors
Terminals
Wires
D6F-01N2-000
D6F-05N2-000
D6F-02L2-000
Model number
1: Vcc
Enlarged view
2: Vout
1: Vcc
2: Vout
3: GND
Molex 51021
Molex 50079
AWG26 or AWG28
D6F-@N2/-02L2
3: GND
1
Minimum order
1

Related parts for D6F-05N2-000

D6F-05N2-000 Summary of contents

Page 1

... LPG ° C and 101.3 kPa. D6F-@N2/-02L2 Model number Minimum order D6F-01N2-000 1 D6F-05N2-000 D6F-02L2-000 Connections D6F-01N2-000 D6F-05N2-000 D6F-02L2-000 Pin No. 1: Vcc 2: Vout 3: GND Connectors Molex 51021 Terminals Molex 50079 Wires AWG26 or AWG28 2: Vout 1: Vcc 3: GND ...

Page 2

... D6F-@N2/-02L2 Dimensions D6F-01N2-000 D6F-05N2-000 Two, M3 screws, Depth: 5 min D6F-02L2-000 3.7 6 ±0.5 21.6 3-17 22.1 ±0.5 8.85 Two, tapered Rc1/4 pipe threads ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. A180-E1-01 In the interest of product improvement, specifications are subject to change without notice ...

Related keywords