ADIS16250ACCZ Analog Devices Inc, ADIS16250ACCZ Datasheet - Page 14

no-image

ADIS16250ACCZ

Manufacturer Part Number
ADIS16250ACCZ
Description
IC ACCEL GYRO SPI PROG 18-LGA
Manufacturer
Analog Devices Inc
Series
iSensor™r
Datasheet

Specifications of ADIS16250ACCZ

Range °/s
±80°/s, ±160°/s, ±320°/s
Sensitivity
±0.2%
Typical Bandwidth
50Hz
Voltage - Supply
4.75 V ~ 5.25 V
Current - Supply
18mA
Output Type
SPI
Operating Temperature
-40°C ~ 85°C
Package / Case
20-LGA
Operating Temperature (min)
-40C
Operating Temperature Classification
Industrial
Operating Temperature (max)
85C
Rad Hardened
No
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
ADIS16250/PCBZ - BOARD EVAL PCB ADIS16250
Lead Free Status / RoHS Status
Compliant, Lead free / RoHS Compliant
ADIS16250/ADIS16255
CALIBRATION
The ADIS16250/ADIS16255 are factory-calibrated for
sensitivity and bias. It also provides several user calibration
functions for simplifying field-level corrections. The calibra-
tion factors are stored in nonvolatile memory and are applied
using the following linear calibration equation:
where:
y is the calibrated output data.
x is the precalibration data.
m is the sensitivity scale factor.
b is the offset scale factor.
There are three options for system-level calibrations of the
bias in the ADIS16250/ADIS16255: auto-null, factory
calibration restore, and manual calibration updates. The
auto-null and factory reset options are described in the
Global Commands section. Optional field-level calibrations
use the preceding equation and require two steps:
1.
2.
The GYRO_OFF provides a calibration range of ±37.5°/sec,
and its contents are nonvolatile. The GYRO_SCALE register
provides a calibration range of 0 to 1.9995, and its contents
are also nonvolatile.
Table 9. GYRO_OFF Register Definition
Address
0x15,
0x14
1
Table 10. GYRO_OFF Bit Descriptions
Bit
15:12
11:0
Table 11. GYRO_SCALE Register Definition
Address
0x17, 0x16
1
2
Table 12. GYRO_SCALE Bit Descriptions
Bit
15:12
11:0
Scale is the weight of each LSB.
Scale is the weight of each LSB.
Equates to a scale factor of one.
y = mx + b
Characterize the behavior of the ADIS16250/ADIS16255
at predefined critical operating conditions.
Use this characterization data to calculate and load the
contents of GYRO_OFF (b) and GYRO_SCALE (m).
Scale
0.018315°/sec
Description
Not used
Data bits
Description
Not used
Data bits
Scale
0.0487%
1
1
Default
0x0800
Default
0x0000
2
Format
Twos
complement
Format
Binary
Access
R/W
Access
R/W
Rev. D | Page 14 of 20
GLOBAL COMMANDS
The ADIS16250/ADIS16255 provide global commands for common
operations such as auto-null, factory calibration restore, manual
flash update, auxiliary DAC latch, and software reset. Each of these
global commands has a unique control bit assigned to it in the
COMMAND register and is initiated by writing a 1 to its assigned bit.
The auto-null function does two things: it resets the contents of the
ANGL_OUT register to zero, and it adjusts the GYRO_OUT register
to zero. This automated adjustment takes two steps:
1.
2.
For optimal calibration accuracy, set the number of filtering taps to
its maximum, wait for the appropriate number of samples to
process through the filter, and then exercise this option.
The factory calibration restore command sets the contents of
GYRO_OFF to 0x0000 and GYRO_SCALE to 0x0800, erasing any
field-level calibration contents. The manual flash update writes the
contents of each nonvolatile register into flash memory for storage.
This process takes approximately 50 ms and requires the power
supply voltage to be within specification for the duration of the
event. It is worth noting that this operation also automatically
follows the auto-null and factory reset commands.
The DAC latch command loads the contents of AUX_DAC into the
DAC latches. Since the AUX_DAC contents must be updated one
byte at a time, this command ensures a stable DAC output voltage
during updates. Finally, the software reset command sends the
ADIS16250/ADIS16255 digital processor into a restart sequence,
effectively doing the same thing as the RST line.
Table 13. COMMAND Register Definition
Address
0x3F, 0x3E
Table 14. COMMAND Bit Descriptions
Bit
15:8
7
6:4
3
2
1
0
Read GYRO_OUT.
Write the opposite of this value into the GRYO_OFF register.
Sensor noise influences the accuracy of this step.
Description
Not used
Software reset command
Not used
Manual flash update command
Auxiliary DAC data latch
Factory calibration restore command
Auto-null command
Default
N/A
Format
N/A
Access
Write only