HMC1021S Honeywell Microelectronics & Precision Sensors, HMC1021S Datasheet - Page 3

SENSOR LINEAR MAGN 1 AXIS 8-SOIC

HMC1021S

Manufacturer Part Number
HMC1021S
Description
SENSOR LINEAR MAGN 1 AXIS 8-SOIC
Manufacturer
Honeywell Microelectronics & Precision Sensors
Type
Linearr
Datasheet

Specifications of HMC1021S

Output Type
Differential Voltage
Sensing Range
±6g
Voltage - Supply
5 V ~ 25 V
Features
Compass - One Axis
Operating Temperature
-55°C ~ 150°C
Package / Case
8-SOIC (0.154", 3.90mm Width)
Sensitivity Range
1mV/V/G
Sensor Terminals
SMD Gull Wing
Leaded Process Compatible
No
Magnetic Field Max
6G
Axis Configuration
Single
Magnetic Field Min
-6G
Sensor Output
Voltage
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Current - Supply
-
Current - Output (max)
-
Lead Free Status / RoHS Status
Lead free / RoHS Compliant, Lead free / RoHS Compliant
Other names
342-1003-2

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Part Number:
HMC1021S
Manufacturer:
honeywell
Quantity:
12 800
Part Number:
HMC1021S-TR
Manufacturer:
STEWART
Quantity:
30 000
Part Number:
HMC1021S-TR
Manufacturer:
HITTITE
Quantity:
20 000
HMC1001/1002/1021/1022
HMC1021/1022 SPECIFICATIONS
Characteristics
Bridge Elements
Set/Reset Straps
Offset Straps
* Tested at 25°C except stated otherwise.
www.honeywell.com
Supply
Resistance
Operating Temperature
Storage Temperature
Field Range
Linearity Error
Hysteresis Error
Repeatability Error
Bridge Offset
Sensitivity
Noise Density
Resolution
Bandwidth
Disturbing Field
Sensitivity Tempco
Bridge Offset Tempco
Bridge Ohmic Tempco
Cross-Axis Effect
Max. Exposed Field
Resistance
Current
Resistance Tempco
Resistance
Offset Constant
Resistance Tempco
0.1% duty cycle, or less, 2 sec current pulse
Cross field = 1 gauss, Happlied = ±1 gauss
Field = 0 gauss after Set pulse, Vb = 5V
Use S/R pulse to restore sensitivity.
No perming effect on zero reading
Full scale (FS) – total applied field
Magnetic signal (lower limit = DC)
Field applied in sensitive direction
T
Vbridge (Vb) referenced to GND
T
T
A
Measured from OFF+ to OFF-
A
A
= -40 to 125°C, With Set/Reset
Sensitivity starts to degrade.
Measured from S/R+ to S/R-
= -40 to 125°C, No Set/Reset
= -40 to 125°C, Ibridge=5mA
3 sweeps across ±2 gauss
3 sweeps across ±2 gauss
Offset = (OUT+) – (OUT-)
Set/Reset Current = 0.5A
T
10Hz Bandwidth, Vb=5V
Bridge current = 10mA
A
= -40 to 125°C, Vb=5V
Best fit straight line
Ambient, unbiased
T
T
T
@ 1Hz, Vb=5V
A
A
A
Conditions*
= -40 to 125°C
= -40 to 125°C
= -40 to 125°C
DC Current
per bridge
± 1 gauss
± 3 gauss
± 6 gauss
Ambient
-0.32
Min
800
-55
-55
-10
0.8
5.5
0.5
4.0
20
38
-6
2
±0.001
±0.05
1100
-0.30
-0.06
0.05
0.08
0.08
±2.5
0.25
+0.3
0.37
0.39
Typ
5.0
0.4
1.6
1.0
7.7
0.5
4.6
48
85
50
5
+11.25
10000
1300
-0.28
Max
1.25
150
175
4.0
6.0
25
+6
60
9
mV/V/gauss
nV/sqrt Hz
mA/gauss
gauss
gauss
gauss
Units
ohms
ohms
ohms
Volts
%/°C
%/°C
%/°C
%/°C
%/°C
%FS
%FS
%FS
gauss
%FS
MHz
Amp
mV
°C
°C
3