ATS625LSGTN-T Allegro Microsystems Inc, ATS625LSGTN-T Datasheet - Page 16

no-image

ATS625LSGTN-T

Manufacturer Part Number
ATS625LSGTN-T
Description
IC SENSOR GEAR TOOTH 4-SIP
Manufacturer
Allegro Microsystems Inc
Type
Special Purposer
Datasheet

Specifications of ATS625LSGTN-T

Sensing Range
60% Trip, 40% Release
Voltage - Supply
4 V ~ 24 V
Current - Supply
14mA
Current - Output (max)
10mA
Output Type
Digital, Open Collector
Features
Gear Tooth Type
Operating Temperature
-40°C ~ 150°C
Package / Case
4-SIP
Rohs Compliant
YES
Lead Free Status / RoHS Status
Lead free / RoHS Compliant

Available stocks

Company
Part Number
Manufacturer
Quantity
Price
Company:
Part Number:
ATS625LSGTN-T
Quantity:
1 388
ATS625LSG
ACCURACY
While the update algorithm will allow the device to adapt to
typical air gap variations, major changes in air gap can adversely
affect switching performance. When characterizing IC perfor-
mance over a significant air gap range, be sure to re-power the
device at each test at different air gaps. This ensures that self-cal-
ibration occurs for each installation condition. See the Operating
Characteristics table and the charts in the Characteristic Data:
Relative Timing Accuracy section for performance information.
REPEATABILITY
Repeatability measurement methodology has been formulated to
minimize the effect of test system jitter on device measurements.
By triggering the measurement instrument, such as an oscillo-
scope, close to the desired output edge, the speed variations that
Target Mechanical Profile
High Resolution Encoder
Low Resolution Encoder
the same output edge
Statistical distribution
of 1000 sweeps for
from pin 1 to pin 4)
Oscilloscope trace
(target movement
Electrical Profile
of 1000 sweeps
Figure 11. Repeatability Measurement Methodology
IC Output
True Zero-Speed Low-Jitter High Accuracy
occur within a single revolution of the target are effectively nul-
lified. Because the trigger event occurs a very short time before
the measured event, little opportunity is given for measurement
system jitter to impact the time-based measurements.
After the data is taken on the oscilloscope, statistical analysis
of the distribution is made to quantify variability and capabil-
ity. Although complete repeatability results can be found in the
Characteristic Data: Repeatability section, figure 11 shows the
correlation between magnetic signal strength and repeatability.
Because an direct relationship exists between magnetic signal
strength and repeatability, optimum repeatability performance
can be attained through minimizing the operating air gap and
optimizing the target design.
X
Oscilloscope triggers at
n events after low-resolution pulse
Next high-resolution encoder pulse
(at target edge)
Gear Tooth Sensor IC
115 Northeast Cutoff
1.508.853.5000; www.allegromicro.com
Allegro MicroSystems, Inc.
Worcester, Massachusetts 01615-0036 U.S.A.
16