HIH-4602-C Honeywell Sensing and Control, HIH-4602-C Datasheet - Page 2

SENSOR HUMIDITY 5.8V 3.5% TO-5

HIH-4602-C

Manufacturer Part Number
HIH-4602-C
Description
SENSOR HUMIDITY 5.8V 3.5% TO-5
Manufacturer
Honeywell Sensing and Control
Datasheet

Specifications of HIH-4602-C

Output Type
Analog Voltage
Sensor Type
Humidity and Temperature
Sensing Accuracy
3.5%
Sensor Output
Voltage
Sensor Terminals
Through Hole
Supply Voltage Range
4VDC To 5.8VDC
Operating Temperature Range
-40°C To +85°C
Humidity Range
0 To 100% RH
Response Time
50s
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
480-3178
HIH-4602-C
Q3497199A
HIH-4602-A/C Series
TABLE 1. PERFORMANCE SPECIFICATIONS (At 5 Vdc supply and 25 ºC [77 ºF] unless otherwise noted.)
FACTORY CALIBRATION DATA
HIH-4602 Sensors are supplied with a calibration and data
printout. See Table 2.
TABLE 2. EXAMPLE DATA PRINTOUT
2
Parameter
Interchangeability (first order curve)
Accuracy (best fit straight line)
Hysterisis
Repeatability
Settling time
Response time (1/e in slow moving air)
Stability (at 50% RH in one year)
Voltage supply
Current supply
Output voltage temp. coefficient at 50% RH, 5 V
Voltage output (1st order curve fit)
Temperature compensation
Operating temperature
Operating humidity
Storage temperature
Storage humidity
Specific Notes:
1. Device is calibrated at 5 Vdc and 25 ºC.
2. Non-condensing environment.
Model
Channel
Wafer
MRP
Calculated values at 5 V
Linear output for 3.5% RH
accuracy at 25 °C
Ratiometric response for
0% RH to 100% RH
V
V
Zero offset
Slope
RH
V
0% RH to 59% RH
60% RH to 100% RH
OUT
OUT
OUT
at 0% RH
at 75.3% RH
www.honeywell.com/sensing
HIH-4602-C
92
030996M
337313
0.826 V
3.198 V
0.826 V
31.483 mV/%RH
(V
(V
V
SUPPLY
OUT
OUT
- zero offset)/slope
- 0.826)/0.0315
(0.1652 to 0.7952)
True RH = (sensor RH)/(1.0546-0.00216T), T in ºC
Minimum
-40[-40]
-50[-58]
-3.5
-5
-8
4
0
V
OUT
TABLE 3. HIH-4602-A NTC THERMISTOR TEMPERATURE
SPECIFICTIONS
TABLE 4. HIH-4602-C RTD TEMPERATURE SENSOR
SPECIFICATIONS
General Notes:
• Sensor is ratiometric to supply voltage.
• Extended exposure to >90% RH causes a reversible shift of
• Sensor is light sensitive. For best performance, shield sensor
=(V
Rb = 100 kOhm ±5% at 25 ºC
Beta = 4250, 25 ºC to 85 ºC
1/T = a + b(Ln R) + c(Ln R) ^ 3, T in degrees K
Low
Mid
High
a = 0.000828083
b = 0.000208691
c = 8.0812E-08
Thin film platinum RTD – Class 2B (Ro: ±0.25%)
DIN EN 60571 (PER IEC 751)
TCR = 3750 ppm/ºC
1000 Ohm at 0 ºC [32 ºF]
See Figure 1.
See Figure 1.
See Figure 2.
3% RH.
from bright light.
SUPPLY
Typical
±0.5
±1.2
200
50
-4
3
)(0.0062(sensor RH) + 0.16), typical at 25 ºC
Maximum
125[257]
85[185]
Temp. ºC
0
50
100
+3.5
500
100
5.8
70
5
8
mV/ºC
% RH
% RH
% RH
% RH
% RH
% RH
ºC[ºF]
ºC[ºF]
% RH
% RH
Unit
Vdc
ms
µA
s
Resistance
351000
33590
5569
Specific
Note
1
2
2

Related parts for HIH-4602-C