A16Z-5070 Omron, A16Z-5070 Datasheet

Background Label

A16Z-5070

Manufacturer Part Number
A16Z-5070
Description
Background Label
Manufacturer
Omron
Type
Emergency Stop Switchr
Datasheets

Specifications of A16Z-5070

Accessory Type
Emergency Stop Name Plate
Label Size
45mm Dia
Colour
Yellow Name Plate
Legend
Blank
Svhc
No SVHC (15-Dec-2010)
Color
Yellow
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With
A16 Series Switches
For Use With/related Products
A16 Series Emergency Stop Switches
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
Other names
A16Z5070
Z1435
Separate Construction with Smallest Class
of Depth in the World
• Direct opening mechanism to open contacts in emergencies,
• Conforms to EN418.
• Includes a safety lock to prevent misuse.
• Features separate construction that allows the Switch to be
• Models available with 3 contacts built into a single block
Note: Be sure to read the precautions for all pushbutton switches in the
Model Number Structure
■ Model Number Legend
Completely Assembled
Shipped as a set that includes the Operation Unit and light source.
D-2
1. Operation Unit Shape and Functions
2. Light Source
Note: Models with separate construction
Code
Code
such as when they are fused.
separated for easier wiring and one-piece-like construction that
allows easier handling.
(A165E-U).
S
LS
M
LM
None
24D
Emergency Stop Switch
A165E
(SPST-NC and DPST-NC) are for
normal loads only. One-piece models
(TPST-NC) are for either normal loads
or microloads.
Pushbutton Switches Group Catalog (Cat. No. X018), as well as
the “Safety Precautions” on page D-11.
Non-lighted
Lighted
Non-lighted
Lighted
Non-lighted
LED
Type
IP65 (Oil-resistant)
Functions
Emergency Stop Switch
Operation
Push-lock,
turn-reset
---
24 VDC
voltage
A165E@-@-@
Pushbutton
30 dia.
40 dia.
---
24 VDC
voltage
Rated
1
2
A165E
3
3. Contacts
Note: TPST-NC models have
Code
01
02
03U
one-piece construction
with the contact unit. Only
non-lighted models are
available.
SPST-NC
DPST-NC
TPST-NC (See note.)
Description

Related parts for A16Z-5070

A16Z-5070 Summary of contents

Page 1

... Models available with 3 contacts built into a single block (A165E-U). Note: Be sure to read the precautions for all pushbutton switches in the Pushbutton Switches Group Catalog (Cat. No. X018), as well as the “Safety Precautions” on page D-11. Model Number Structure ■ ...

Page 2

... LED 24 VDC Non-lighted --- Note: The above models have a surface indication of “RESET.” Models with “STOP” indication are also available. For further information, contact your OMRON representative. ■ Individual Parts (for Switches with Separate Construction) Operation Units Appearance Illumination 30 dia. ...

Page 3

... A Models with One-piece Construction Rated voltage Resistive load 125 VAC 1 A 250 VAC 0 VDC 1 A D-4 Emergency Stop Switch Type Model Yellow, 45 dia. A16Z-5070 Rectangular A16ZJ-3003 Square A16ZA-3003 Round A16ZT-3003 --- A16Z-3004 A16Z-5080 Standards UL508, CSA C22.2 No.14 EN60947-5-1 GB14048.5 mark. ...

Page 4

... IP65 Oil-resistant Electric shock protection class Class II PTI (tracking characteristic) 175 Degree of contamination 3 (EN60947-5-1) Weight Approx (in case of DPST-NC Switches) Note: LED not mounted. Test them with the LED removed. ■ Operating Characteristics Features Operating force (OF) max. 14.7 N Releasing force (RF) min. 0.1 N·m Pretravel (PT) 3 ...

Page 5

Nomenclature (Models with Separate Construction) \ Protective Structure and Terminal Type Protective Structure Oil-resistant IP65 Terminal Type Solder terminals (tab terminals #110) Lamp LED lamp Note: A165E Emergency Stop Switch must be ordered as a set. No LED is installed ...

Page 6

Dimensions Note: All units are in millimeters unless otherwise indicated. A165E-S 30 dia. Non-lighted models 30 mm diameter +0.1 3 dia. 0 Panel cutout dimensions A165E-LS 30 dia. Lighted models 30 mm diameter +0.1 3 dia. 0 Panel cutout dimensions ...

Page 7

A165E-M 40 dia. Non-lighted models 40 mm diameter +0.1 3 +0.2 16 dia. 0 Panel cutout dimensions A165E-LM Lighted models 40 dia diameter +0.2 16 dia. 0 Panel cutout dimensions A165E-M-03U One-body models 40 dia diameter ...

Page 8

... Accessories Yellow Plate (Vinyl Chloride) A16Z-5070 15.6 dia. 45 dia. Lock Ring Rough surface 15.8 0.1 dia. Rough surface 0 15 dia. 0.1 ■ Terminal Arrangement SPST Switches Note: The L+ and L terminals are not available with the non-lighted models. Panel Plugs Select an appropriate Panel Plug according to the panel design and mount from the front side of the panel ...

Page 9

... Lock ring Rubber packing or Yellow Plate (sold separately) Mounting nut 3. Removing the Switch Insert the prongs of the A16Z-5080 Extractor between the Switch and the Operation Unit, grip the Switch, and pull to remove. L marking 4. Installing the LED Lamp When mounting the Lamp, make sure it is facing the direction shown in the following diagram ...

Page 10

... Others The oil-resistant IP65 uses NBR rubber and is resistant to general cutting oil and cooling oil. Some particular oils cannot be used with the oil-resistant IP65, however, so contact your OMRON representative for details. When painting or coating the panel, make sure that the specified panel dimensions apply to the panel after painting or coating ...

Page 11

... Cancellation; Etc. Orders are not subject to rescheduling or cancellation unless Buyer indemnifies Omron against all related costs or expenses. 10. Force Majeure. Omron shall not be liable for any delay or failure in delivery resulting from causes beyond its control, including earthquakes, fires, floods, strikes or other labor disputes, shortage of labor or materials, accidents to machinery, acts of sabotage, riots, delay in or lack of transportation or the requirements of any government authority ...

Page 12

Cat. No. GC SAFETY-3 07/05 Specifications subject to change without notice Printed in USA ...