TO-3-15423/EZ MOELLER, TO-3-15423/EZ Datasheet

CAM SWITCH, CO

TO-3-15423/EZ

Manufacturer Part Number
TO-3-15423/EZ
Description
CAM SWITCH, CO
Manufacturer
MOELLER
Datasheet

Specifications of TO-3-15423/EZ

No. Of Poles
3
No. Of Switch Positions
3
Contact Current Ac Max
20A
Svhc
No SVHC (18-Jun-2010)
Angle
90°
External Depth
35mm
External Length / Height
48mm
External Width
48mm
Ip/nema Rating
IP55
Indexing
RoHS Compliant
Type: T0−3−15423/E
Article No.: 034109
Sales text GROUP SWITCH
With black thumb−grip and grey front plate
One contact closed per step
(without overlap)
Contact sequence
Front plate no.
1
Ordering information
Design
Pole
General
Standards
Flush mounting
3
IEC/EN 60947, VDE 0660,
IEC/EN 60204, CSA, UL
Switch−disconnectors to
IEC/EN 60947−3
Load−break switches to

Related parts for TO-3-15423/EZ

TO-3-15423/EZ Summary of contents

Page 1

... With black thumb−grip and grey front plate One contact closed per step (without overlap) Ordering information Design Pole Contact sequence Front plate no. General Standards 1 Flush mounting 3 IEC/EN 60947, VDE 0660, IEC/EN 60204, CSA, UL Switch−disconnectors to IEC/EN 60947−3 Load−break switches to ...

Page 2

... Load rating with intermittent operation, class Short−circuit rating Fuse Rated short−time withstand current (1 s current) Safe isolation to VDE 0106 Part 101 and Part 101/A1 between the contacts Switching angles Contact units Double−break contacts Current heat loss per contact ...

Page 3

... Rated breaking capacity, motor load switch cos = 0.35 230 V 400 V 500 V 690 V Rated operational current 440 V load−break switch AC−21A AC−3 motor load switch motor rating 230 V 230 V Star−delta 400 V 400 V Star−delta 500 V 500 V Star−delta 690 V 690 V Star−delta AC− ...

Page 4

... DC−1, Load−break switches L Rated operational current Voltage per contact pair in series DC−21A Rated operational current 240 V 240 V Contacts DC−23A, motor load switch L Rated operational current Contacts 48 V Rated operational current Contacts 60 V Rated operational current Contacts 120 V Rated operational current ...

Page 5

... T0(3), (6), (8)...: Maximum of 2 cross−section sizes difference admissible between 2 conductors T5(B)−...: Maximum of 1 cross−section size difference admissible between 2 conductors For type T8−3−8342/... the following applies: switching angle = 90° and flat connection = 1 busbar 25 × busbars 20 × 3 For mechanical shock ...

Page 6

... Dimensions Characteristic curve For utilisation category AC−4 (extreme load: 100 % inching, reversing or plugging) The blocked rotor current of the motor should not exceed the rated current of the switch for AC−21A to ensure a reasonable device lifespan. Moeller GmbH, Hein−Moeller−Str. 7−11, D−53115 Bonn E− ...

Related keywords