Y92A-48 Omron, Y92A-48 Datasheet

no-image

Y92A-48

Manufacturer Part Number
Y92A-48
Description
DUST COVER
Manufacturer
Omron
Datasheets

Specifications of Y92A-48

Rohs Compliant
YES
Accessory Type
Cover
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
For Use With/related Products
H5CX-A/-L
Lead Free Status / Rohs Status
Lead free / RoHS Compliant
For Use With
H7CZ Series Digital Counters
Lead Free Status / RoHS Status
Lead free / RoHS Compliant
Other names
Y92A48
Easy to Use and Easy to Read.
Basic Features
Safety and Reliability
Other Features
Features
Basic Features
Better Readability
Character Height of 10 mm with a Wide Viewing Angle.
The Easiest Operation
Operation is simplified by the Up Key for
each digit.
Safety and Reliability
Isolated Power Supply and Input Circuits
Power supply circuit and input circuits are isolated inside the Counter.
Previous non-isolated counters had wiring restrictions and could be
damaged if wired incorrectly. The H7CZ removes these worries.
• Character height of 10 mm for better readability.
• Operation is simplified by the Up Key for each digit.
• Power supply circuit and input circuits are isolated inside the
• Set value limit function prevents unexpected operation of output
• Output counter function helps in managing the service life of the
• Waterproof, dust-proof structure (UL508 Type 4X and IP66).
• Key protection.
Counter.
devices caused by setting mistakes.
Counter or the load.
Digital Counter
H7CZ
New Product
Refer to Safety Precautions on page 17.
10 mm
(actual size)
Confirmation
Clear
Easy to read from the top,
bottom, and sides.
Set Value Limit
You can set an upper limit for the set value to prevent unexpected
operation of output devices caused by setting mistakes.
Output Counter
The output counter counts the number of times the output turns ON
(alarms can be displayed and the count can be monitored in
increments of 1,000 operations). This counter is useful in managing
the service life of the Counter or the load.
Other Features
Waterproof, Dust-proof Structure (UL508 Type
4X and IP66)
Worry-free application is possible in locations subject to water.
Note: When the Y92S-29 Waterproof Packing is used.
Key Protection
Select from any of seven protection patterns. Use the best one for the
application.
For 1,000 pieces
Setting the upper limit of the set
value enables worry-free operation.
No overflow
1

Related parts for Y92A-48

Y92A-48 Summary of contents

Page 1

New Product Digital Counter H7CZ Easy to Use and Easy to Read. Basic Features • Character height for better readability. • Operation is simplified by the Up Key for each digit. Safety and Reliability • Power supply ...

Page 2

... Contact output (SPDT) Type Remarks --- Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Power supply Model voltage 100 to 240 VAC H7CZ- VDC/24 VAC H7CZ-L8D1 Page ...

Page 3

H7CZ Multifunction Preset Counter Specifications Ratings Item Models Configuration *1 Power supply voltage Operating voltage fluctuation Ratings range Power consumption Mounting method External connections Degree of protection Input signals Maximum counting speed Input mode Output mode Counter One-shot output time ...

Page 4

... Immunity Surge: EN 61000-4- line to lines (power and output lines); Immunity Voltage Dip/Interruption: EN 61000-4-11: 0.5 cycle, 100% (rated voltage) * The following safety standards apply to H7CZ. cUL (Listing): Applicable when an OMRON P2CF(-E) Socket is used. cUR (Recognition): Applicable when any other socket is used. I/O Functions *1 Using as a Counter • ...

Page 5

Connections Block Diagram (Basic insulation) Power supply Output circuit circuit (Basic insulation) (Basic insulation) Display circuit Internal Input circuits control circuit Key switch circuit Terminal Arrangement Confirm that the power supply meets specifications before use. H7CZ-L8/L8D1 1-stage Contact Output Internal ...

Page 6

... Timers. If they are mounted side-by-side, water- resistance will be lost. n Units mounted side by side A +1 A=(48n−2.5) −0 With Y92A-48F1 attached. +1 A={48n−2.5+(n−1)×4} −0 With Y92A-48 attached. +1 A=(51n−5.5) −0 ...

Page 7

... Soft Cover Hard Cover Y92A-48F1 Y92A-48 Protecting the Counter in Environments Subject to Oil The H7CZ's panel surface is water-resistive (conforming to IP@6, UL Type 4X) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. ...

Page 8

... Eight, M3.5 x 7.5 set screws Note: Round crimp terminals cannot be used on Finger-safe Sockets. Use forked crimp terminals. Back-connecting Sockets Model P3G-08 45 Note: A Y92A-48G Terminal Cover can be used with the Socket to create a finger-safe construction. Terminal Covers for P3G-08 Back-connecting Socket Model Y92A-48G Twelve, 6.4-dia. holes 34 Y92A-48G 47 ...

Page 9

Optional Products for Track Mounting Mounting Track PFP-100N 4.5 PFP-50N Mounting Track PFP-100N2 4.5 End Plate PFP-M Spacer PFP-S Note: Order Spacers in increments of 10 1,000 (500)* * The values ...

Page 10

H7CZ Operating Procedures Setting Procedure Guide Change to Function Setting Mode. Power min. Function Run mode setting mode * min. *1. If the mode is switched to the function setting mode during ...

Page 11

To previous From previous page page Set value • Set each digit using the individual U Key. upper limit (SL- Key protect • Set the key protect level using the U Key. level (KYPT) kp-1 (KP-1) ...

Page 12

H7CZ Explanation of Functions Input Mode (cntm) Set increment mode (UP) or decrement mode (DOWN) as the input mode. Output Mode (outm) Set the way that control output for the present value is output. The possible settings are N, F, ...

Page 13

Operation in Run Mode • Set values for each digit as required using the U Key. Present value Set value • Present Value Shows the present count value. • Set Values Set the set values. When the present value reaches ...

Page 14

H7CZ Input/Output Mode Settings UP Reset 999999 Set value N 0 OUT Reset 999999 Set value F 0 OUT Reset 999999 Output Set value mode C setting 0 OUT Reset 999999 Set value R 0 OUT Reset 999999 Set value ...

Page 15

Input mode UP Reset 999999 Set value P 0 OUT Reset 999999 Output Set value mode Q setting 0 OUT Reset 999999 Set value A 0 OUT Note: 1. When the present value reaches 999999, it returns ...

Page 16

H7CZ Key Protect Level It is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-7) when the key-protect switch is set to ON. The key protect level ...

Page 17

Safety Precautions for All H7CZ Series (Common) CAUTION Do not allow pieces of metal, wire clippings, or fine metallic shavings or fillings from installation to enter the product. Doing so may occasionally result in electric shock, fire, or malfunction. Minor ...

Page 18

H7CZ Precautions for Correct Use • An inrush current of approx will flow for a short time when the power supply is turned ON. If the capacity of the power supply is not sufficient, the Counter may not ...

Page 19

... OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE ...

Page 20

... Room 2211, Bank of China Tower, 200 Yin Cheng Zhong Road, PuDong New Area, Shanghai, 200120, China Tel: (86) 21-5037-2222/Fax: (86) 21-5037-2200 Authorized Distributor: © OMRON Corporation 2009 All Rights Reserved. In the interest of product improvement, specifications are subject to change without notice. CSM_6_1_0411 Printed in Japan Cat ...

Related keywords