3RF20201AA02 SIEMENS, 3RF20201AA02 Datasheet - Page 23

SSR, 20A, 24-230VAC

3RF20201AA02

Manufacturer Part Number
3RF20201AA02
Description
SSR, 20A, 24-230VAC
Manufacturer
SIEMENS
Datasheet

Specifications of 3RF20201AA02

Control Voltage Range
24Vdc
Operating Voltage Range
24VAC To 230VAC
Load Current
20A
Isolation Voltage
600V
Control Voltage Type
DC
Blocking Voltage
800V
Control Current Max
15mA
Control Current Typ
2mA
Relay Terminals
Screw
Power controllers
Overview
Power controllers for SIRIUS SC solid-state switching
devices
The following functions have been integrated:
• Power control regulator with proportional-action control
• Inrush current limitation: With the aid of an adjustable
• Load circuit monitoring for detecting load failure, alloyed
Selection and ordering data
Power controllers
4/24
for adjusting the power of the connected load. Here, the
setpoint is set with a rotary knob on the module as a
percentage with reference to the 100 % power stored as a
setpoint. In this way the power is kept constant even in the
event of voltage fluctuations or a change in load resistance.
voltage ramp, the inrush current is limited by means of phase
control. This is useful above all with loads such as lamps
which have an inrush transient current.
power semiconductors, lack of voltage or a break in the load
circuit.
3RF29 Function Modules
Siemens LV 1 · 2006
Rated operating current
I
A
Rated control supply voltage 24 V AC/DC
20
20
50
50
90
90
Rated control supply voltage 110 V AC
20
20
50
50
90
90
e
Rated operating voltage
U
V
110 … 230
400 … 600
110 … 230
400 … 600
110 … 230
400 … 600
110 … 230
400 … 600
110 … 230
400 … 600
110 … 230
400 … 600
e
DT Order No.
A
A
A
A
A
A
A
A
A
A
A
A
Application
The power controller adjusts the current in the connected load
by means of a solid-state switching device depending on a
setpoint. Changes in the mains voltage or in the load resistance
are thus compensated by the power controller. The setpoint can
be predefined externally as a 0 to 10 V signal or internally by
means of a potentiometer. Depending on the setting of the
potentiometer (t
principle of full-wave control or generalized phase control.
Full-wave control
In this operating mode the output is adjusted to the required
setpoint by changing the on-to-off period. The period duration is
predefined at one second.
Generalized phase control
In this operating mode the output is adjusted to the required
setpoint by changing the current flow angle. In order to observe
the limit values of the conducted interference voltage for
industrial networks, a choke rated at at least 200 mH must be
included in the load circuit.
3RF29 20-0HA13
3RF29 20-0HA16
3RF29 50-0HA13
3RF29 50-0HA16
3RF29 90-0HA13
3RF29 90-0HA16
3RF29 20-0HA33
3RF29 20-0HA36
3RF29 50-0HA33
3RF29 50-0HA36
3RF29 90-0HA33
3RF29 90-0HA36
R
), the adjustment is carried out according to the
* You can order this quantity or a multiple thereof.
Price
per PU
PU
(UNIT,
SET, M)
1
1
1
1
1
1
1
1
1
1
1
1
PS*
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
1 unit
PG
101
101
101
101
101
101
101
101
101
101
101
101
Weight
per PU
approx.
kg
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175
0.175

Related parts for 3RF20201AA02